Technische Zeichnung — ABB 1SAM250000R1013 — 1SAM250000R1013 — Motor protection circuit-breaker

Technische Zeichnung. Representative component image; exact configuration and appearance may vary. Abbildungen dienen nur als Referenz. Das gelieferte Teil kann anders aussehen.

ABB

1SAM250000R1013 — Motor protection circuit-breaker

Elektrotechnik & Steuerungen

Teilenummer: 1SAM250000R1013

ABB MS116-20, part number 1SAM250000R1013, is a three-pole manual motor starter with an adjustable 16–20 A overload setting. It provides overload, short-circuit and phase-loss protection, with a rotary manual control and trip class 10A. The device is suitable for single-phase and three-phase applications, subject to correct selection and connection.

Sie suchen ABB 1SAM250000R1013? Diese Katalogreferenz ist als „Elektrotechnik & Steuerungen“ eingeordnet. Senden Sie die Teilenummer und Ihre Gerätedaten, damit wir Spezifikation und Verfügbarkeit prüfen und ein Angebot inklusive Versand erstellen können.

Verfügbarkeit auf Anfrage

Preis auf Anfrage

Versand inklusiveGarantie & ServiceAngebot für dieses Teil erhalten

Technische Daten

HerstellerABB
Teilenummer1SAM250000R1013
KategorieElektrotechnik & Steuerungen
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-20
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length85.4 mm
Product Net Weight0.31 kg
Rated Service Short-Circuit Breaking Capacity (I cs )10 kA at 230 V AC and 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )16 kA at 230 V AC and 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )300 A
Setting Range16–20 A
Rated Operational Power AC-3 (P e )7.5 kW at 400 V, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 7.5 kW
Rated Operational VoltageMain circuit: 690 V AC
Rated Operational Current (I e )20 A
Rated Operational Current AC-3 (I e )20 A
Rated Operational Current AC-3e (I e )20 A
Rated Frequency (f)Main circuit: 50/60 Hz
Rated Impulse Withstand Voltage (U imp )6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 1.5 ... 2.3 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 20 A
Degree of ProtectionHousing IP20
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Tightening TorqueMain Circuit 2 N·m
Wire Stripping LengthMain Circuit 10 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip class10A

Katalogangaben können fehlerhaft oder veraltet sein. Vollständige Spezifikationen und geprüfte Angaben erhalten Sie auf Anfrage. Bitte bestätigen Sie vor der Bestellung die Teilenummer und die Eignung für Ihre Maschine mit uns.