Technische Zeichnung. Representative component image; exact configuration and appearance may vary. Abbildungen dienen nur als Referenz. Das gelieferte Teil kann anders aussehen.
1SAM340000R1007 — Power circuit-breaker for trafo/generator/installation protection
Elektrotechnik & SteuerungenTeilenummer: 1SAM340000R1007
ABB MS132-2.5T (1SAM340000R1007) is a three-pole circuit breaker designed for primary-side control transformer protection. It provides adjustable overload protection from 1.6 to 2.5 A, short-circuit protection and manual disconnection. The device has screw terminals and a rotary operating handle. Confirm the transformer and installation requirements before selection.
Sie suchen ABB 1SAM340000R1007? Diese Katalogreferenz ist als „Elektrotechnik & Steuerungen“ eingeordnet. Senden Sie die Teilenummer und Ihre Gerätedaten, damit wir Spezifikation und Verfügbarkeit prüfen und ein Angebot inklusive Versand erstellen können.
Verfügbarkeit auf Anfrage
Technische Daten
| Hersteller | ABB |
|---|---|
| Teilenummer | 1SAM340000R1007 |
| Kategorie | Elektrotechnik & Steuerungen |
| Time-Current Characteristic Curve | Tripping characteristic - Circuit Breaker for Transformer Protection MS132-2.5T |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 86.75 mm |
| Product Net Weight | 0.265 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 100 kA at 230 V AC and 400 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 100 kA at 400 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 50 A |
| Setting Range | 1.6–2.5 A |
| Rated Operational Voltage | Main circuit: 690 V AC |
| Rated Operational Current (I e ) | 2.5 A |
| Rated Frequency (f) | Main circuit: 50/60 Hz |
| Operating Frequency (f sw ) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.6 ... 1.6 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 2.5 A |
| Degree of Protection | Housing: IP20; main circuit terminals: IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Tightening Torque | Main Circuit 0.8 ... 1.2 N·m |
| Wire Stripping Length | Main Circuit 9 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Minimum Mounting Distance | Electrical Conductive Board, Vertical 75 mm |
| Short-Circuit Current Rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA |
| Published component type | Power circuit-breaker for trafo/generator/installation protection |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip Class | 10 |
Katalogangaben können fehlerhaft oder veraltet sein. Vollständige Spezifikationen und geprüfte Angaben erhalten Sie auf Anfrage. Bitte bestätigen Sie vor der Bestellung die Teilenummer und die Eignung für Ihre Maschine mit uns.
Fragen zum Produkt
Für dieses Teil liegen noch keine Rechercheergebnisse auf Deutsch vor. Unser Team hilft Ihnen gerne weiter.
Angebot für dieses Teil erhalten