Technische Zeichnung — ABB 1SAM350000R1010 — 1SAM350000R1010 — Motor protection circuit-breaker

Technische Zeichnung. Representative component image; exact configuration and appearance may vary. Abbildungen dienen nur als Referenz. Das gelieferte Teil kann anders aussehen.

ABB

1SAM350000R1010 — Motor protection circuit-breaker

Elektrotechnik & Steuerungen

Teilenummer: 1SAM350000R1010

ABB 1SAM350000R1010 is the MS132-10 three-pole manual motor starter and motor protection circuit-breaker. It provides manual switching and protection against overload, short circuit and phase failure, with an adjustable 6.3–10 A overload setting. It is rated at 4 kW for three-phase AC-3 operation at 400 V and has screw terminals and a rotary handle with ON, OFF and TRIP indication.

Sie suchen ABB 1SAM350000R1010? Diese Katalogreferenz ist als „Elektrotechnik & Steuerungen“ eingeordnet. Senden Sie die Teilenummer und Ihre Gerätedaten, damit wir Spezifikation und Verfügbarkeit prüfen und ein Angebot inklusive Versand erstellen können.

Verfügbarkeit auf Anfrage

Preis auf Anfrage

Versand inklusiveGarantie & ServiceAngebot für dieses Teil erhalten

Technische Daten

HerstellerABB
Teilenummer1SAM350000R1010
KategorieElektrotechnik & Steuerungen
Ex Operating InstructionsATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS132-10.0
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS132
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA at 230 V AC; 100 kA at 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )100 kA at 230 V AC; 100 kA at 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )150 A
Setting Range6.3–10 A
Rated Operational Power AC-3 (P e )4 kW at 400 V, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 4 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (I e )10 A
Rated Operational Current AC-3 (I e )10 A
Rated Operational Current AC-3e (I e )10 A
Rated Operational Current DC-5 (I e )10 A
Rated Frequency (f)Main circuit: 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.8 ... 2.0 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 10 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Mounting on DIN RailTH35-7.5 or TH35-15
Contact Position IndicationON / OFF / TRIP
Overload Trip Class10

Katalogangaben können fehlerhaft oder veraltet sein. Vollständige Spezifikationen und geprüfte Angaben erhalten Sie auf Anfrage. Bitte bestätigen Sie vor der Bestellung die Teilenummer und die Eignung für Ihre Maschine mit uns.

Fragen zum Produkt

Für dieses Teil liegen noch keine Rechercheergebnisse auf Deutsch vor. Unser Team hilft Ihnen gerne weiter.

Angebot für dieses Teil erhalten

Fühlen Sie sich zu Hause.

Wählen Sie Ihre Sprache und Ihr Lieferziel. Endgültige Preise und Versandbedingungen werden in Ihrem Angebot bestätigt.