Technische Zeichnung. Representative component image; exact configuration and appearance may vary. Abbildungen dienen nur als Referenz. Das gelieferte Teil kann anders aussehen.
1SAM350000R1011 — Motor protection circuit-breaker
Elektrotechnik & SteuerungenTeilenummer: 1SAM350000R1011
ABB 1SAM350000R1011, type MS132-16, is a three-pole manual motor starter and motor protection circuit-breaker with an adjustable 10–16 A overload setting and trip class 10. It provides manual switching and protection against overload, short circuit and phase failure. The device has screw terminals, a lockable rotary handle and a 45 mm wide housing.
Sie suchen ABB 1SAM350000R1011? Diese Katalogreferenz ist als „Elektrotechnik & Steuerungen“ eingeordnet. Senden Sie die Teilenummer und Ihre Gerätedaten, damit wir Spezifikation und Verfügbarkeit prüfen und ein Angebot inklusive Versand erstellen können.
Verfügbarkeit auf Anfrage
Technische Daten
| Hersteller | ABB |
|---|---|
| Teilenummer | 1SAM350000R1011 |
| Kategorie | Elektrotechnik & Steuerungen |
| Ex Operating Instructions | ATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS132-16.0 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS132 |
| Product Net Width | 45 mm |
| Product Net Height | 97.8 mm |
| Product Net Depth / Length | 86.55 mm |
| Product Net Weight | 0.31 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 100 kA at 230 V AC and 400 V AC; 20 kA at 440 V AC and 500 V AC; 3 kA at 690 V AC; 10 kA at 250 V DC with three poles in series |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 100 kA at 230 V AC and 400 V AC; 20 kA at 440 V AC and 500 V AC; 3 kA at 690 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 240 A |
| Setting Range | 10–16 A |
| Rated Operational Power AC-3 (P e ) | 7.5 kW at 400 V, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 7.5 kW |
| Rated Operational Voltage | Main circuit 690 V AC; 250 V DC with three poles in series |
| Rated Operational Current (I e ) | 16 A |
| Rated Operational Current AC-3 (I e ) | 16 A |
| Rated Operational Current AC-3e (I e ) | 16 A |
| Rated Operational Current DC-5 (I e ) | 16 A |
| Rated Frequency (f) | 50/60 Hz |
| Operating Frequency (f sw ) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 1.1 ... 2.8 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 16 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Extended product type | MS132-16 |
| Trip class | 10 |
| Rated operational current (Ie) | 16 A |
| Mounting | TH35-7.5 or TH35-15 DIN rail |
| Actuator | Rotary handle with ON/OFF/TRIP indication |
Katalogangaben können fehlerhaft oder veraltet sein. Vollständige Spezifikationen und geprüfte Angaben erhalten Sie auf Anfrage. Bitte bestätigen Sie vor der Bestellung die Teilenummer und die Eignung für Ihre Maschine mit uns.
Fragen zum Produkt
Für dieses Teil liegen noch keine Rechercheergebnisse auf Deutsch vor. Unser Team hilft Ihnen gerne weiter.
Angebot für dieses Teil erhalten