1SAM451000R1016 — Motor protection circuit-breaker
Elektrotechnik & SteuerungenTeilenummer: 1SAM451000R1016
ABB 1SAM451000R1016 is an MS165-54 three-pole manual motor starter and motor protection circuit breaker. It has a 40–54 A adjustable overload setting, trip class 10, screw terminals and a lockable rotary handle. The device provides overload, phase-failure and short-circuit protection and is rated 22 kW for three-phase AC-3 operation at 400 V. Verify motor current and installation fault level before selection.
Sie suchen ABB 1SAM451000R1016? Diese Katalogreferenz ist als „Elektrotechnik & Steuerungen“ eingeordnet. Senden Sie die Teilenummer und Ihre Gerätedaten, damit wir Spezifikation und Verfügbarkeit prüfen und ein Angebot inklusive Versand erstellen können.
Verfügbarkeit auf Anfrage
Technische Daten
| Hersteller | ABB |
|---|---|
| Teilenummer | 1SAM451000R1016 |
| Kategorie | Elektrotechnik & Steuerungen |
| Ex Operating Instructions | ATEX - Operating instructions for MS165 for potentially explosive areas |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS165-54 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400/690V -Manual Motor Starter MS165/MO165 |
| Product Net Width | 55 mm |
| Product Net Height | 142.65 mm |
| Product Net Depth / Length | 122.1 mm |
| Product Net Weight | 0.97 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 30 kA at 230 V AC; 30 kA at 400 V AC; 20 kA at 500 V AC; 6 kA at 690 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 50 kA at 230 V AC; 50 kA at 400 V AC; 20 kA at 500 V AC; 8 kA at 690 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 810 A |
| Setting Range | 40–54 A |
| Rated Operational Power AC-3 (P e ) | 22 kW at 400 V, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 22 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Rated Operational Current (I e ) | 54 A |
| Rated Operational Current AC-3 (I e ) | 54 A |
| Rated Operational Current AC-3e (I e ) | 54 A |
| Rated Operational Current DC-5 (I e ) | 54 A |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Operating Frequency (f sw ) | 0 ... 415 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 8 kV |
| Rated Insulation Voltage (U i ) | 1000 V |
| Power Loss | at Rated Operating Conditions per Pole 3.84 ... 6.99 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 54 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 35 mm² |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip class | 10 |