2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device
Elektrotechnik & SteuerungenTeilenummer: 2CSA275103R1204
2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device — ABB reference 2CSA275103R1204. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Sie suchen ABB 2CSA275103R1204? Diese Katalogreferenz ist als „Elektrotechnik & Steuerungen“ eingeordnet. Senden Sie die Teilenummer und Ihre Gerätedaten, damit wir Spezifikation und Verfügbarkeit prüfen und ein Angebot inklusive Versand erstellen können.
Verfügbarkeit auf Anfrage
Technische Daten
| Hersteller | ABB |
|---|---|
| Teilenummer | 2CSA275103R1204 |
| Kategorie | Elektrotechnik & Steuerungen |
| Type of Residual Current | Type A |
| Test Voltage (Ut) | 170 … 264 V |
| Dielectric Test Voltage | 2.5 kV |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 10 kA |
| Rated Residual Breaking Capacity (IΔm) | 6 kA |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 7.5 kA |
| Power Supply Connection | Arbitrary |
| Number of Protected Poles | 1 |
| Number of Poles | 1P+N |
| Operating Characteristic | Instantaneous |
| Position of Neutral Terminals | Right |
| Tightening Torque | 2.8 N·m |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Mounting Position of Accessories | Right |
| Connecting Capacity | Busbar 10 mm² |
| Wire Stripping Length | 12 mm |
| Terminal Type | Screw Terminals |
| Rated Operational Voltage | 230...240 V AC |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (I n ) | 20 A |
| Rated Residual Current | 30 mA |
| Rated Short-Circuit Capacity | 10 kA |
| Rated Frequency (f) | 50 … 60 Hz |
| Power Loss | 4.2 W |
| Overvoltage Category | III |
| Ambient Air Temperature | Operation -25 ... 55 °C |
| Published component type | Earth leakage circuit breaker with auxiliary device |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Katalogangaben können fehlerhaft oder veraltet sein. Vollständige Spezifikationen und geprüfte Angaben erhalten Sie auf Anfrage. Bitte bestätigen Sie vor der Bestellung die Teilenummer und die Eignung für Ihre Maschine mit uns.