Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.
1SAE231111R0630 — Installation Contactor
contactorPart number: 1SAE231111R0630
ABB 1SAE231111R0630 is the ESB25-30N-06 three-pole installation contactor, with three normally open main contacts and a 230–240 V control circuit. It is rated 25 A in AC-1 and 9 A in AC-3 under the specified operating conditions. Dimensions are 36 × 85 × 65 mm (W × H × D). Confirm the control supply and load requirements before selection.
Looking for ABB 1SAE231111R0630? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAE231111R0630 |
| Category | Electrical & controls |
| Product Net Width | 36 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.23 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main circuit: 400 V AC; 220 V DC |
| Rated Frequency (f) | Control circuit: 50 Hz, 60 Hz, 400 Hz and DC; main circuit: 50 Hz, 60 Hz and DC |
| Rated Operational Current AC-1 (I e ) | (NO) 25 A |
| Rated Operational Current AC-3 (I e ) | 9 A at 230 V single-phase or 400 V three-phase, normally open |
| Rated Operational Current AC-7a (I e ) | (NO) 25 A |
| Rated Operational Current AC-7b (I e ) | 9 A at 230 V single-phase or 400 V three-phase, normally open |
| Rated Operational Power AC-1 (P e ) | 5.8 kW at 230 V single-phase; 17.3 kW at 400 V three-phase, normally open |
| Rated Operational Power AC-3 (P e ) | 1.3 kW at 230 V single-phase; 4 kW at 400 V three-phase, normally open |
| Rated Operational Power AC-7a (P e ) | 5.8 kW at 230 V single-phase; 17.3 kW at 400 V three-phase, normally open |
| Rated Operational Power AC-7b (P e ) | 1.3 kW at 230 V single-phase; 4 kW at 400 V three-phase, normally open |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U c ) | 230 ... 240 V |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 2 W |
| Published component type | Installation Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Degree of protection | IP20 |
| Ambient air temperature | Operation: -25 to +55 °C; storage: -40 to +80 °C |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What control voltage does the ABB ESB25-30N-06 require?
The rated control circuit voltage is 230–240 V. The published control circuit frequencies include 50, 60 and 400 Hz, as well as DC. Check the supply voltage and type before selection.
How many contacts does 1SAE231111R0630 have?
It is a three-pole contactor with three normally open main contacts and no normally closed main contacts.
Is this 25 A contactor suitable for a motor load?
The rating depends on the utilization category: AC-1 is 25 A, while AC-3 is 9 A at 230 V single-phase or 400 V three-phase. The listed AC-3 power is 1.3 kW and 4 kW respectively. Check the motor and circuit requirements before selection.
What are the dimensions and main-circuit voltage ratings?
The contactor measures 36 mm wide, 85 mm high and 65 mm deep. Its listed main-circuit operational voltages are 400 V AC and 220 V DC; check the load category and application before use.
Researched on:
Research information may be outdated. Confirm fitment and specifications with our team before ordering.