Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.
1SAE232111R0640 — Installation Contactor
contactorPart number: 1SAE232111R0640
ABB EN25-40N-06 (1SAE232111R0640) is a four-pole installation contactor with four normally open main contacts and a 230–240 V AC/DC control circuit. Rated 25 A for AC-1 duty, it provides automatic operation and a manual override for switching single- or three-phase loads.
Looking for ABB 1SAE232111R0640? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAE232111R0640 |
| Category | Electrical & controls |
| Product Net Width | 36 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.24 kg |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Rated Operational Voltage | Main Circuit 220 V DC |
| Rated Frequency (f) | Control Circuit 400 Hz |
| Rated Operational Current AC-1 (I e ) | (NO) 25 A |
| Rated Operational Current AC-3 (I e ) | (230 V) Single Phase, NO 9 A |
| Rated Operational Current AC-7a (I e ) | (NO) 25 A |
| Rated Operational Current AC-7b (I e ) | (230 V) Single Phase, NO 9 A |
| Rated Operational Power AC-1 (P e ) | (230 V) Single Phase, NO 5.8 kW |
| Rated Operational Power AC-3 (P e ) | (230 V) Single Phase, NO 1.3 kW |
| Rated Operational Power AC-7a (P e ) | (230 V) Single Phase, NO 5.8 kW |
| Rated Operational Power AC-7b (P e ) | (230 V) Single Phase, NO 1.3 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 4 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U c ) | 230–240 V AC/DC |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 2 W |
| Published component type | Installation Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Width in modular spacings | 2 |
| Manual operating modes | Manual off, automatic, manual on with return to automatic |
| Degree of protection | IP20 |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What control voltage does the ABB EN25-40N-06 require?
The EN25-40N-06, order code 1SAE232111R0640, has a rated control circuit voltage of 230–240 V AC or DC. Check the control supply separately from the voltage and rating of the switched load.
How many contacts does 1SAE232111R0640 have?
It is a four-pole contactor with four normally open main contacts and no normally closed main contacts. Verify the contact arrangement and control voltage against the device being replaced.
Is the EN25-40N-06 rated for a 25 A motor?
The 25 A rating is for AC-1 duty, not a blanket motor rating. ABB lists 1.3 kW at 230 V single-phase under AC-3 for this part. Confirm the motor nameplate, duty and protection requirements before selecting it.
Does this contactor have a manual override?
Yes. It has manual off, automatic and manual on positions. Manual on returns to automatic when the coil is next energised; confirm the operating mode before relying on it for a particular control circuit.
How much panel width does the EN25-40N-06 require?
The contactor is 36 mm wide, equivalent to two modular spacings. Check the available installation space and any accessory or ventilation requirements before ordering.
Researched on: