Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.
1SAE341111R0122 — Installation Contactor
contactorPart number: 1SAE341111R0122
ABB 1SAE341111R0122 is an ESB40-22N-01 four-pole installation contactor with a 24 V AC/DC control coil and two normally open plus two normally closed main contacts. Its AC-1 operational current is 40 A on the normally open contacts and 30 A on the normally closed contacts. The contactor occupies three modular spacings.
Looking for ABB 1SAE341111R0122? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAE341111R0122 |
| Category | Electrical & controls |
| Product Net Width | 54 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.405 kg |
| Number of Main Contacts NO | 2 |
| Number of Main Contacts NC | 2 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Rated Operational Voltage | Main circuit: 400 V AC; 220 V DC |
| Rated Frequency (f) | Control circuit: DC, 50 Hz, 60 Hz, 400 Hz; main circuit: DC, 50 Hz, 60 Hz |
| Rated Operational Current AC-1 (I e ) | NO: 40 A; NC: 30 A |
| Rated Operational Current AC-3 (I e ) | (230 V) Single Phase, NO 22 A |
| Rated Operational Current AC-7a (I e ) | (NO) 40 A |
| Rated Operational Current AC-7b (I e ) | (230 V) Single Phase, NO 22 A |
| Rated Operational Power AC-1 (P e ) | 230 V single-phase: NO 9.2 kW; NC 6.9 kW |
| Rated Operational Power AC-3 (P e ) | (230 V) Single Phase, NO 3.7 kW |
| Rated Operational Power AC-7a (P e ) | 230 V single-phase: NO 9.2 kW; NC 6.9 kW |
| Rated Operational Power AC-7b (P e ) | (230 V) Single Phase, NO 3.7 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U c ) | 24 V AC/DC |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 3 W |
| Published component type | Installation Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Width in Number of Modular Spacings | 3 |
| Degree of Protection | IP20 |
| Ambient Air Temperature | Operation: -25 to +55 °C; storage: -40 to +80 °C |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What control voltage does ABB 1SAE341111R0122 require?
The ESB40-22N-01 has a 24 V AC/DC control coil. Check the control supply separately from the main circuit voltage.
How many normally open and normally closed contacts does this contactor have?
It is a four-pole contactor with two normally open and two normally closed main contacts. No auxiliary contacts are included in the stated contact count.
Is the ESB40-22N-01 rated 40 A on all contacts?
No. Its AC-1 operational current is 40 A on the normally open contacts and 30 A on the normally closed contacts. Select the rating for the load and utilization category.
Can this contactor switch a motor load?
For AC-3 operation, the listed normally open contact rating is 22 A and 3.7 kW at 230 V single-phase. Verify the motor and circuit requirements before selection.
What are the contactor dimensions and panel width?
The listed net dimensions are 54 mm wide, 85 mm high and 65 mm deep. The contactor occupies three modular spacings.
Researched on: