1SAE341111R0622 — Installation Contactor
contactorPart number: 1SAE341111R0622
ABB 1SAE341111R0622 is an ESB40-22N-06 four-pole installation contactor with two normally open and two normally closed main contacts and a 230 V AC/DC control coil. It uses screw terminals and DIN rail mounting. The AC-1 current rating is 40 A for normally open contacts and 30 A for normally closed contacts.
Looking for ABB 1SAE341111R0622? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAE341111R0622 |
| Category | Electrical & controls |
| Product Net Width | 54 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.405 kg |
| Number of Main Contacts NO | 2 |
| Number of Main Contacts NC | 2 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Rated Operational Voltage | Main circuit: 400 V AC; 220 V DC |
| Rated Frequency (f) | Control circuit: DC, 50, 60 and 400 Hz; main circuit: DC, 50 and 60 Hz |
| Rated Operational Current AC-1 (I e ) | Normally open: 40 A; normally closed: 30 A |
| Rated Operational Current AC-3 (I e ) | (230 V) Single Phase, NO 22 A |
| Rated Operational Current AC-7a (I e ) | (NO) 40 A |
| Rated Operational Current AC-7b (I e ) | (230 V) Single Phase, NO 22 A |
| Rated Operational Power AC-1 (P e ) | 230 V single-phase: 6.9 kW normally closed; 9.2 kW normally open |
| Rated Operational Power AC-3 (P e ) | (230 V) Single Phase, NO 3.7 kW |
| Rated Operational Power AC-7a (P e ) | 230 V single-phase: 6.9 kW normally closed; 9.2 kW normally open |
| Rated Operational Power AC-7b (P e ) | (230 V) Single Phase, NO 3.7 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U c ) | 230 V AC/DC |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 3 W |
| Published component type | Installation Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Mounting | DIN rail |
| Terminal Type | Screw terminals |
| Width in Modular Spacings | 3 |
| Degree of Protection | IP20 |
| Ambient Operating Temperature | -25 to +55 °C |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What coil voltage and contact arrangement does ABB 1SAE341111R0622 have?
The ESB40-22N-06 has a 230 V AC/DC control coil and four main contacts: two normally open and two normally closed.
Are all four contacts on the ESB40-22N-06 rated for 40 A?
No. The AC-1 rating is 40 A for the normally open contacts and 30 A for the normally closed contacts. Select the contactor according to the load and utilization category.
Can the ESB40-22N-06 switch a motor load?
Its normally open contacts are rated 22 A AC-3 and 3.7 kW at 230 V single phase. Check the motor and control requirements before selecting it; the 40 A general rating does not apply to every load.
How much panel space does the ABB 1SAE341111R0622 need?
The contactor is 54 mm wide, 85 mm high and 65 mm deep, with a width of three modular spacings. It mounts on a DIN rail and uses screw terminals.
Can this contactor replace the one in my equipment?
Replacement suitability cannot be confirmed from the part number alone. Check the existing contact arrangement, coil supply, load ratings and mounting; provide the equipment model and serial number for verification.
Researched on:
Research information may be outdated. Confirm fitment and specifications with our team before ordering.