Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.
1SAE341111R0631 — Installation Contactor
contactorPart number: 1SAE341111R0631
ABB 1SAE341111R0631 is an ESB40-31N-06 four-pole installation contactor with three normally open and one normally closed main contacts. It has a rated control voltage of 230 V and a listed AC-1 current of 40 A on the normally open contacts. Check the contact arrangement, load category and circuit ratings before selection.
Looking for ABB 1SAE341111R0631? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAE341111R0631 |
| Category | Electrical & controls |
| Product Net Width | 54 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.405 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Rated Operational Voltage | Main circuit: 400 V AC; 220 V DC |
| Rated Frequency (f) | Control circuit: 50 Hz, 60 Hz, 400 Hz and DC; main circuit: 50 Hz, 60 Hz and DC |
| Rated Operational Current AC-1 (I e ) | Normally open: 40 A; normally closed: 30 A |
| Rated Operational Current AC-3 (I e ) | Normally open: 22 A at 230 V single-phase or 400 V three-phase |
| Rated Operational Current AC-7a (I e ) | (NO) 40 A |
| Rated Operational Current AC-7b (I e ) | Normally open: 22 A at 230 V single-phase or 400 V three-phase |
| Rated Operational Power AC-1 (P e ) | (230 V) Single Phase, NC 6.9 kW |
| Rated Operational Power AC-3 (P e ) | (230 V) Single Phase, NO 3.7 kW |
| Rated Operational Power AC-7a (P e ) | (230 V) Single Phase, NC 6.9 kW |
| Rated Operational Power AC-7b (P e ) | (230 V) Single Phase, NO 3.7 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U c ) | 230 V |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 3 W |
| Published component type | Installation Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Ambient operating temperature | −25 to +55 °C |
| Degree of protection | IP20 |
| Width in modular spacings | 3 |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What is the coil voltage of ABB 1SAE341111R0631?
The rated control circuit voltage is 230 V. This is separate from the main-circuit operational voltage, listed as 400 V AC or 220 V DC.
How many contacts does the ESB40-31N-06 have?
It is a four-pole contactor with three normally open and one normally closed main contacts. Verify the contact arrangement and control voltage against the equipment before ordering.
Is the 40 A rating suitable for every load on this contactor?
No. The listed AC-1 current is 40 A for the normally open contacts and 30 A for the normally closed contact. For AC-3, the normally open contacts are rated 22 A at 230 V single-phase or 400 V three-phase. Select according to load and operating conditions.
What are the dimensions of the 1SAE341111R0631 contactor?
The listed net dimensions are 54 mm wide, 85 mm high and 65 mm deep, with a net weight of 0.405 kg. Its width is three modular spacings.
Researched on: