Technical illustration. Published product/series reference; confirm the exact configuration and supplied appearance. Images are for reference only. The supplied part’s appearance may differ.
1SAE342111R0620 — Installation Contactor
contactorPart number: 1SAE342111R0620
ABB 1SAE342111R0620 is an EN40-20N-06 two-pole installation contactor with two normally open main contacts and a 230 V AC/DC control circuit. It is rated 40 A for AC-1 duty and offers On, Off and Auto operation. At 230 V single-phase, its AC-3 rating is 22 A and 3.7 kW. The unit mounts on a DIN rail and is 54 mm wide.
Looking for ABB 1SAE342111R0620? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAE342111R0620 |
| Category | Electrical & controls |
| Product Net Width | 54 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.375 kg |
| Number of Main Contacts NO | 2 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 2P |
| Rated Operational Voltage | Main circuit: 220 V DC; 400 V AC |
| Rated Frequency (f) | Control circuit: 50 Hz, 60 Hz, 400 Hz and DC; main circuit: 50 Hz, 60 Hz and DC |
| Rated Operational Current AC-1 (I e ) | (NO) 40 A |
| Rated Operational Current AC-3 (I e ) | (230 V) Single Phase, NO 22 A |
| Rated Operational Current AC-7a (I e ) | (NO) 40 A |
| Rated Operational Current AC-7b (I e ) | (230 V) Single Phase, NO 22 A |
| Rated Operational Power AC-1 (P e ) | (230 V) Single Phase, NO 9.2 kW |
| Rated Operational Power AC-3 (P e ) | (230 V) Single Phase, NO 3.7 kW |
| Rated Operational Power AC-7a (P e ) | (230 V) Single Phase, NO 9.2 kW |
| Rated Operational Power AC-7b (P e ) | (230 V) Single Phase, NO 3.7 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 4 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U c ) | 230 V AC/DC |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 3 W |
| Published component type | Installation Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Manual operating modes | On, Off, Auto |
| Mounting | DIN rail |
| Width in modular spacings | 3 |
| Degree of Protection | IP20 |
| Ambient air temperature, operation | -25 to +55 °C |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What control voltage does the ABB EN40-20N-06 require?
The control circuit is rated at 230 V and can be operated with AC or DC. Check the control supply separately from the voltage of the load being switched.
What are the contact arrangement and number of poles?
The 1SAE342111R0620 has two poles and two normally open main contacts, with no normally closed main contacts. It has no built-in auxiliary contacts.
Is the 40 A rating suitable for a motor load?
The 40 A rating is for AC-1 and AC-7a duty. For AC-3 or AC-7b duty at 230 V single-phase, the listed rating is 22 A and 3.7 kW. Check the motor and duty requirements before selection.
Does this contactor have a manual override?
Yes. The EN40-20N-06 has manual On and Off positions as well as Auto mode. Confirm the intended operating arrangement before selecting it.
What space and mounting does the EN40-20N-06 require?
The contactor is listed for DIN-rail mounting and measures 54 mm wide, 85 mm high and 65 mm deep. Its width occupies three modular spacings; allow for the enclosure and wiring requirements.
Researched on: