Technical illustration. Published product/series reference; confirm the exact configuration and supplied appearance. Images are for reference only. The supplied part’s appearance may differ.
1SAE342111R0640 — Installation Contactor
contactorPart number: 1SAE342111R0640
ABB 1SAE342111R0640 is the EN40-40N-06 four-pole installation contactor, with four normally open main contacts and a 230 V AC/DC control circuit. It is rated 40 A for AC-1 duty and includes manual override for switching single- or three-phase loads. Check the load category and electrical ratings for the intended installation.
Looking for ABB 1SAE342111R0640? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAE342111R0640 |
| Category | Electrical & controls |
| Product Net Width | 54 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.41 kg |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Rated Operational Voltage | Main circuit: 220 V DC; 400 V AC |
| Rated Frequency (f) | Control circuit: DC, 50, 60 or 400 Hz; main circuit: DC, 50 or 60 Hz |
| Rated Operational Current AC-1 (I e ) | (NO) 40 A |
| Rated Operational Current AC-3 (I e ) | 22 A, NO, at 230 V single-phase or 400 V three-phase |
| Rated Operational Current AC-7a (I e ) | (NO) 40 A |
| Rated Operational Current AC-7b (I e ) | 22 A, NO, at 230 V single-phase or 400 V three-phase |
| Rated Operational Power AC-1 (P e ) | (230 V) Single Phase, NO 9.2 kW |
| Rated Operational Power AC-3 (P e ) | 3.7 kW at 230 V single-phase; 11 kW at 400 V three-phase, NO |
| Rated Operational Power AC-7a (P e ) | (230 V) Single Phase, NO 9.2 kW |
| Rated Operational Power AC-7b (P e ) | (230 V) Single Phase, NO 3.7 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 4 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U c ) | 230 V AC/DC |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 3 W |
| Published component type | Installation Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Mounting on DIN Rail | TH35-7.5 or TH35-15, 35 mm rail |
| Terminal Type | Screw terminals |
| Degree of Protection | IP20 |
| Width in Number of Modular Spacings | 3 |
| Operating Temperature | -25 to +55 °C |
| Manual Control | On, Off and Auto selector |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What control voltage and contact configuration does ABB 1SAE342111R0640 have?
The EN40-40N-06 has a 230 V AC/DC rated control circuit and four normally open main contacts, with no normally closed main contacts. Check the control supply and required contact arrangement before ordering.
Is the EN40-40N-06 rated for a 40 A motor load?
Not automatically. Its AC-1 rating is 40 A, while its AC-3 rating is 22 A at 230 V single-phase or 400 V three-phase. The listed AC-3 power is 3.7 kW at 230 V single-phase or 11 kW at 400 V three-phase. Select against the actual load and duty.
Can the ABB EN40-40N-06 be operated manually?
Yes. It has a manual override as well as automatic operation. The selector has Off, Auto and On positions; the manual On position returns to automatic when the coil is next energized.
How much panel space does the 1SAE342111R0640 require?
The contactor is 54 mm wide, 85 mm high and 65 mm deep, and occupies three modular spacings. It mounts on a 35 mm DIN rail; check the enclosure and wiring clearances for the installation.
Researched on:
Research information may be outdated. Confirm fitment and specifications with our team before ordering.