1SAM250000R1011 — Motor protection circuit-breaker

Electrical & controls

Part number: 1SAM250000R1011

ABB MS116-16 (1SAM250000R1011) is a three-pole manual motor starter and motor protection circuit-breaker with an adjustable 10–16 A overload setting. It provides thermal overload and electromagnetic short-circuit protection, phase-loss sensitivity and manual switching. The device has screw terminals, a trip class of 10A and a rated operational current of 16 A.

Looking for ABB 1SAM250000R1011? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerABB
Part number1SAM250000R1011
CategoryElectrical & controls
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-16
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )16 kA at 230 V AC; 16 kA at 400 V AC; 6 kA at 440 V AC; 4 kA at 500 V AC; 2 kA at 690 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )16 kA at 230 V AC; 16 kA at 400 V AC; 15 kA at 440 V AC; 10 kA at 500 V AC; 3 kA at 690 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )240 A
Setting Range10–16 A
Rated Operational Power AC-3 (P e )7.5 kW at 400 V AC, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 7.5 kW
Rated Operational Voltage690 V AC, main circuit
Rated Operational Current (I e )16 A
Rated Operational Current AC-3 (I e )16 A
Rated Operational Current AC-3e (I e )16 A
Rated Frequency (f)50/60 Hz, main circuit
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 1.1 ... 2.8 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 16 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10A
Mounting on DIN RailTH35-7.5 or TH35-15, 35 mm DIN rail

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

What motor current range does ABB MS116-16 cover?

The adjustable thermal overload range is 10–16 A. The motor rated current must fall within that range; also check the supply, starting conditions and prospective fault current before selecting the device.

What is the MS116-16 short-circuit breaking capacity at 400 V?

At 400 V AC, ABB lists both the service breaking capacity (Ics) and ultimate breaking capacity (Icu) as 16 kA. Check the prospective fault current and the applicable backup protection requirements for the installation.

Can the MS116-16 protect a 7.5 kW motor?

ABB lists 7.5 kW at 400 V for three-phase AC-3 operation. Power alone does not establish suitability: check the motor nameplate current against the 10–16 A setting range and verify the full circuit ratings.

Can the MS116-16 be used with a single-phase motor?

ABB describes the MS116 as suitable for single- and three-phase applications. It is a three-pole device; the correct connection and suitability depend on the circuit and motor ratings. Refer to ABB’s documentation and have the installation assessed by a qualified electrician.

What protection does the ABB MS116-16 provide?

It combines adjustable thermal overload protection with electromagnetic short-circuit protection and phase-loss sensitivity. Its overload trip class is 10A; the rated instantaneous short-circuit setting is 240 A.

Researched on:

Research information may be outdated. Confirm fitment and specifications with our team before ordering.

Get a quote for this part

Make yourself at home.

Choose your language and delivery destination. Final pricing and shipping are confirmed in your quote.