Technical illustration — ABB 1SAM340000R1007 — 1SAM340000R1007 — Power circuit-breaker for trafo/generator/installation protection

Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.

ABB

1SAM340000R1007 — Power circuit-breaker for trafo/generator/installation protection

Electrical & controls

Part number: 1SAM340000R1007

ABB MS132-2.5T (1SAM340000R1007) is a three-pole circuit breaker designed for primary-side control transformer protection. It provides adjustable overload protection from 1.6 to 2.5 A, short-circuit protection and manual disconnection. The device has screw terminals and a rotary operating handle. Confirm the transformer and installation requirements before selection.

Looking for ABB 1SAM340000R1007? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerABB
Part number1SAM340000R1007
CategoryElectrical & controls
Time-Current Characteristic CurveTripping characteristic - Circuit Breaker for Transformer Protection MS132-2.5T
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA at 230 V AC and 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )100 kA at 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )50 A
Setting Range1.6–2.5 A
Rated Operational VoltageMain circuit: 690 V AC
Rated Operational Current (I e )2.5 A
Rated Frequency (f)Main circuit: 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.6 ... 1.6 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 2.5 A
Degree of ProtectionHousing: IP20; main circuit terminals: IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Published component typePower circuit-breaker for trafo/generator/installation protection
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

What is ABB 1SAM340000R1007 designed to protect?

ABB identifies MS132-2.5T as a breaker for primary-side control transformer protection. It provides overload and short-circuit protection and manual disconnection. Check the transformer and installation requirements before selecting it.

What current range and short-circuit trip setting does the MS132-2.5T have?

Its overload setting range is 1.6–2.5 A, with a rated operational current of 2.5 A and a fixed instantaneous short-circuit setting of 50 A. Check the transformer nameplate and protection requirements to confirm selection.

What is the breaking capacity of the MS132-2.5T at 400 V AC?

The rated service short-circuit breaking capacity Ics and ultimate breaking capacity Icu are each 100 kA at 400 V AC. Verify the prospective fault current and applicable installation requirements before use.

How does the MS132-2.5T connect and mount?

This three-pole breaker has screw terminals and mounts on a 35 mm DIN rail. The housing is IP20 and the main-circuit terminals are IP10. Confirm panel clearance and the equipment model and serial number before replacing an installed breaker.

Researched on:

Research information may be outdated. Confirm fitment and specifications with our team before ordering.

Get a quote for this part

Make yourself at home.

Choose your language and delivery destination. Final pricing and shipping are confirmed in your quote.