1SAM340000R1013 — MS132-20T Switch for transformer protection MS13220T
Electrical & controlsPart number: 1SAM340000R1013
ABB MS132-20T (1SAM340000R1013) is a three-pole circuit breaker for primary-side protection of control transformers against overload and short circuit. It has an adjustable 16–20 A overload range, a fixed 400 A instantaneous short-circuit setting, screw terminals and a rotary disconnect handle.
Looking for ABB 1SAM340000R1013? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAM340000R1013 |
| Category | Electrical & controls |
| Published component description | MS132-20T Switch for transformer protection MS13220T |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Overload setting range | 16–20 A |
| Rated operational current Ie | 20 A |
| Rated operational voltage Ue | 690 V AC |
| Rated frequency | 50/60 Hz |
| Number of poles | 3 |
| Rated instantaneous short-circuit setting Ii | 400 A |
| Rated service breaking capacity Ics | 100 kA at 400 V AC |
| Rated ultimate breaking capacity Icu | 100 kA at 400 V AC |
| Overload trip class | 10 |
| Terminal type | Screw terminals |
| Degree of protection | Housing IP20; main-circuit terminals IP10 |
| Mounting | TH35-7.5 or TH35-15 DIN rail |
| Product width | 45 mm |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What does ABB 1SAM340000R1013 protect?
The MS132-20T is designed for overload and short-circuit protection on the primary side of control transformers. It also has a manual disconnect function.
What is the MS132-20T overload setting range?
The adjustable overload setting range is 16–20 A, with a rated operational current of 20 A. The transformer nominal current must fall within the setting range; check the full electrical design before selection.
What is the short-circuit trip setting and breaking capacity?
The instantaneous short-circuit setting is fixed at 400 A, intended to accommodate transformer inrush. The rated service breaking capacity is 100 kA at 400 V AC; breaking capacity and any backup protection depend on voltage.
Can the MS132-20T be mounted on a DIN rail, and what terminals does it use?
Yes. ABB specifies TH35-7.5 and TH35-15 mounting rails. This MS132-20T version uses screw terminals; the housing is IP20 and the main-circuit terminals are IP10.