Technical illustration — ABB 1SAM350000R1006 — 1SAM350000R1006 — Motor protection circuit-breaker

Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.

ABB

1SAM350000R1006 — Motor protection circuit-breaker

Electrical & controls

Part number: 1SAM350000R1006

ABB MS132-1.6 (1SAM350000R1006) is a three-pole manual motor starter and motor protection circuit-breaker with an adjustable 1.0–1.6 A overload setting. It provides overload and short-circuit protection and phase-failure sensitivity, with a trip class 10 overload release. The screw-terminal device has a rotary ON/OFF/TRIP handle and is rated 0.55 kW for three-phase AC-3 operation at 400 V.

Looking for ABB 1SAM350000R1006? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerABB
Part number1SAM350000R1006
CategoryElectrical & controls
Ex Operating InstructionsATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS132-1.6 valid for production date from week 34/2014
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS132
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA at 230 V AC and 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )100 kA at 230 V AC and 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )20 A
Setting Range1.0–1.6 A
Rated Operational Power AC-3 (P e )(400 V) Three Phase 0.55 kW
Rated Operational Power AC-3e (P e )(400 V) Three Phase 0.55 kW
Rated Operational VoltageMain circuit: 690 V AC; 250 V DC
Rated Operational Current (I e )1.6 A
Rated Operational Current AC-3 (I e )1.6 A
Rated Operational Current AC-3e (I e )1.6 A
Rated Operational Current DC-5 (I e )1.6 A
Rated Frequency (f)Main circuit: 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.6 ... 1.7 W
Number of Poles3P
Conventional Free-air Thermal Current (I th )Main Circuit 1.6 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Overload Trip Class10
Mounting on DIN RailTH35-7.5 or TH35-15, according to IEC 60715
Actuator TypeRotary handle; ON/OFF/TRIP indication

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

What motor current range does the ABB MS132-1.6 cover?

The overload setting range is 1.0–1.6 A, with a rated operational current of 1.6 A. Check the motor nameplate current and the complete circuit requirements before selecting the breaker.

What motor power and short-circuit capacity is this breaker rated for at 400 V?

For three-phase AC-3 operation at 400 V, the listed motor power is 0.55 kW. The rated service and ultimate short-circuit breaking capacities are each 100 kA at 400 V AC. Confirm the actual motor current and prospective fault level for the installation.

What protection and operating functions does the MS132-1.6 provide?

This three-pole manual motor starter provides overload and short-circuit protection and is sensitive to phase failure. It has a rotary handle with ON, OFF and TRIP indication; its overload trip class is 10.

How is the 1SAM350000R1006 mounted and connected?

It has screw terminals and can mount on TH35-7.5 or TH35-15 DIN rail. The listed net dimensions are 45 mm wide, 90 mm high and 86.75 mm deep. Check panel clearances and wiring requirements for the installation.

Researched on:

Research information may be outdated. Confirm fitment and specifications with our team before ordering.

Get a quote for this part

Make yourself at home.

Choose your language and delivery destination. Final pricing and shipping are confirmed in your quote.