ABB 1SAM350000R1007 is the MS132-2.5 three-pole motor protection circuit-breaker, also called a manual motor starter. It has an adjustable 1.6–2.5 A overload setting, screw terminals and a 0.75 kW three-phase AC-3 rating at 400 V. The unit uses thermal and electromagnetic protection and has a rotary operating handle.
Looking for ABB 1SAM350000R1007? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAM350000R1007 |
| Category | Electrical & controls |
| Ex Operating Instructions | ATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS132-2.5 valid for production date form week 34/2014 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS132 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 86.75 mm |
| Product Net Weight | 0.265 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 100 kA at 230 V AC; 100 kA at 400 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 100 kA at 230 V AC; 100 kA at 400 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 31.3 A |
| Setting Range | 1.6–2.5 A |
| Rated Operational Power AC-3 (P e ) | 0.75 kW at 400 V AC, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 0.75 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Rated Operational Current (I e ) | 2.5 A |
| Rated Operational Current AC-3 (I e ) | 2.5 A |
| Rated Operational Current AC-3e (I e ) | 2.5 A |
| Rated Operational Current DC-5 (I e ) | 2.5 A |
| Rated Frequency (f) | 50/60 Hz, main circuit |
| Operating Frequency (f sw ) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.7 ... 1.8 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 2.5 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What current range does the ABB MS132-2.5 protect?
The thermal overload setting range is 1.6–2.5 A, with a rated operational current of 2.5 A. Check the motor nameplate current and circuit requirements before selecting the breaker.
Can the MS132-2.5 be used with a 0.75 kW motor at 400 V?
Its listed AC-3 operational power is 0.75 kW at 400 V, three-phase. This rating alone does not confirm suitability: check motor nameplate current, starting conditions and the installation requirements.
What is the short-circuit breaking capacity at 400 V AC?
The listed ultimate breaking capacity Icu is 100 kA at 400 V AC; the listed service breaking capacity Ics is also 100 kA at 400 V AC. Verify the prospective fault current and applicable installation requirements.
What are the dimensions and connections of 1SAM350000R1007?
The breaker is listed as 45 mm wide, 90 mm high and 86.75 mm deep. It has three poles and screw terminals. Check panel space and conductor suitability before installation.