Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.
1SAM350000R1010 — Motor protection circuit-breaker
Electrical & controlsPart number: 1SAM350000R1010
ABB 1SAM350000R1010 is the MS132-10 three-pole manual motor starter and motor protection circuit-breaker. It provides manual switching and protection against overload, short circuit and phase failure, with an adjustable 6.3–10 A overload setting. It is rated at 4 kW for three-phase AC-3 operation at 400 V and has screw terminals and a rotary handle with ON, OFF and TRIP indication.
Looking for ABB 1SAM350000R1010? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAM350000R1010 |
| Category | Electrical & controls |
| Ex Operating Instructions | ATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS132-10.0 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS132 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 86.75 mm |
| Product Net Weight | 0.265 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 100 kA at 230 V AC; 100 kA at 400 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 100 kA at 230 V AC; 100 kA at 400 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 150 A |
| Setting Range | 6.3–10 A |
| Rated Operational Power AC-3 (P e ) | 4 kW at 400 V, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 4 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Rated Operational Current (I e ) | 10 A |
| Rated Operational Current AC-3 (I e ) | 10 A |
| Rated Operational Current AC-3e (I e ) | 10 A |
| Rated Operational Current DC-5 (I e ) | 10 A |
| Rated Frequency (f) | Main circuit: 50/60 Hz |
| Operating Frequency (f sw ) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.8 ... 2.0 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 10 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Mounting on DIN Rail | TH35-7.5 or TH35-15 |
| Contact Position Indication | ON / OFF / TRIP |
| Overload Trip Class | 10 |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What current range does the ABB MS132-10 cover?
The overload setting range is 6.3–10 A, with a rated operational current of 10 A. Check the motor nameplate current and the installation requirements before selecting the breaker.
What motor power and short-circuit breaking capacity are specified at 400 V?
The MS132-10 is rated for 4 kW three-phase AC-3 operation at 400 V. Its rated service short-circuit breaking capacity, Ics, is 100 kA at 400 V AC. Check the prospective fault current and applicable ratings for the installation.
Can the MS132-10 be used with a single-phase motor?
ABB’s product information describes this three-pole starter as suitable for single-phase and three-phase applications. Confirm the correct connection and motor current against ABB’s instructions and the actual installation before use.
How is the MS132-10 mounted and connected?
It uses screw terminals and can be mounted on TH35-7.5 or TH35-15 DIN rail. The enclosure is IP20; the main circuit terminals are IP10.
Researched on:
Research information may be outdated. Confirm fitment and specifications with our team before ordering.