ABB MS132-25, part 1SAM350000R1014, is a three-pole manual motor starter and motor protection circuit-breaker with a 20–25 A adjustable overload setting. It provides manual switching, overload and short-circuit protection, phase-loss sensitivity and a disconnect function. The device has screw terminals and a lockable rotary handle, and is rated 11 kW for three-phase AC-3 operation at 400 V.

Looking for ABB 1SAM350000R1014? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerABB
Part number1SAM350000R1014
CategoryElectrical & controls
Ex Operating InstructionsATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS132-25.0
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS132
Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length86.55 mm
Product Net Weight0.31 kg
Rated Service Short-Circuit Breaking Capacity (I cs )(230 V AC) 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(230 V AC) 50 kA
Rated Instantaneous Short-Circuit Current Setting (I i )375 A
Setting Range20 ... 25 A
Rated Operational Power AC-3 (P e )(400 V) Three Phase 11 kW
Rated Operational Power AC-3e (P e )(400 V) Three Phase 11 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (I e )25 A
Rated Operational Current AC-3 (I e )25 A
Rated Operational Current AC-3e (I e )25 A
Rated Operational Current DC-5 (I e )25 A
Rated Frequency (f)Main circuit: 50 / 60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 1.8 ... 2.8 W
Number of Poles3P
Conventional Free-air Thermal Current (I th )Main Circuit 25 A
Degree of ProtectionHousing IP20
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Extended Product TypeMS132-25
Trip Class10
Rated Service Short-Circuit Breaking Capacity at 400 V AC50 kA
Mounting on DIN RailTH35-7.5 or TH35-15
Degree of Protection - Main Circuit TerminalsIP10
Actuator TypeLockable rotary handle
Contact Position IndicationON / OFF / TRIP

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

What current range and motor rating does the ABB MS132-25 cover?

The overload setting range is 20–25 A, and its rated operational current is 25 A. Its AC-3 and AC-3e rating is 11 kW for a three-phase motor at 400 V. Check the motor nameplate current, supply, starting conditions and protection coordination before selection.

What is the short-circuit breaking capacity of 1SAM350000R1014?

The rated service short-circuit breaking capacity Ics is 50 kA at 400 V AC and 50 kA at 230 V AC. The rating depends on voltage and configuration; verify the prospective fault current and protection coordination for the installation.

Can the MS132-25 be used with a single-phase motor?

ABB describes the MS132-25 as suitable for single- and three-phase applications. Suitability for a particular motor depends on its current, voltage and the applicable connection arrangement; have a qualified person verify the application and manufacturer instructions.

What protection and switching functions does the MS132-25 provide?

It provides overload and short-circuit protection, phase-loss sensitivity, manual switching and a disconnect function. It has a trip-free mechanism and a lockable rotary handle. Phase-loss sensitivity should not be treated as a guarantee of protection in every operating condition; a qualified person should assess the motor protection scheme.

How is the MS132-25 mounted and connected?

It has screw terminals and can be mounted on a TH35-7.5 or TH35-15 DIN rail. The housing is IP20 and the main circuit terminals are IP10. Check enclosure and wiring requirements for the installation.

Researched on:

Research information may be outdated. Confirm fitment and specifications with our team before ordering.

Get a quote for this part

Make yourself at home.

Choose your language and delivery destination. Final pricing and shipping are confirmed in your quote.