1SAM451000R1014 — Motor protection circuit-breaker
Electrical & controlsPart number: 1SAM451000R1014
ABB 1SAM451000R1014 is the MS165-32 three-pole manual motor starter and motor protection circuit-breaker. It has a 23–32 A adjustable overload setting, thermal and electromagnetic protection, screw terminals and a rotary operating handle. ABB lists a 15 kW AC-3 rating at 400 V.
Looking for ABB 1SAM451000R1014? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAM451000R1014 |
| Category | Electrical & controls |
| Ex Operating Instructions | ATEX - Operating instructions for MS165 for potentially explosive areas |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS165-32 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400/690V -Manual Motor Starter MS165/MO165 |
| Product Net Width | 55 mm |
| Product Net Height | 142.65 mm |
| Product Net Depth / Length | 122.1 mm |
| Product Net Weight | 0.97 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | (230 V AC) 100 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | (230 V AC) 100 kA |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 480 A |
| Setting Range | 23–32 A |
| Rated Operational Power AC-3 (P e ) | 15 kW at 400 V, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 15 kW |
| Rated Operational Voltage | 690 V AC; 250 V DC with three poles in series |
| Rated Operational Current (I e ) | 32 A |
| Rated Operational Current AC-3 (I e ) | 32 A |
| Rated Operational Current AC-3e (I e ) | 32 A |
| Rated Operational Current DC-5 (I e ) | 32 A |
| Rated Frequency (f) | 50/60 Hz |
| Operating Frequency (f sw ) | 0 ... 415 Hz |
| Rated Impulse Withstand Voltage (U imp ) | 8 kV |
| Rated Insulation Voltage (U i ) | 1000 V |
| Power Loss | at Rated Operating Conditions per Pole 2.27 ... 4.40 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 32 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible conductor with ferrule: 1 or 2 × 1–35 mm² |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What current range does ABB MS165-32 cover?
The overload setting range is 23–32 A. ABB advises selecting a starter so the actual motor current falls within its setting range; check the motor nameplate and application requirements.
What motor power is MS165-32 rated for at 400 V?
ABB lists 15 kW at 400 V for AC-3 operation. Power alone is not enough to select the starter: check the motor current against its 23–32 A setting range and verify the application.
What protection does 1SAM451000R1014 provide?
The MS165-32 uses thermal overload and electromagnetic short-circuit protection, with phase-loss sensitivity. Its overload trip class is 10; it also has a manual disconnect function.
Can MS165-32 be used on a single-phase motor?
ABB describes the MS165 as suitable for single- and three-phase applications. Confirm the motor current, circuit arrangement and applicable ABB wiring information before selecting it.
Researched on:
Research information may be outdated. Confirm fitment and specifications with our team before ordering.