1SAM451000R1016 — Motor protection circuit-breaker
Electrical & controlsPart number: 1SAM451000R1016
ABB 1SAM451000R1016 is an MS165-54 three-pole manual motor starter and motor protection circuit breaker. It has a 40–54 A adjustable overload setting, trip class 10, screw terminals and a lockable rotary handle. The device provides overload, phase-failure and short-circuit protection and is rated 22 kW for three-phase AC-3 operation at 400 V. Verify motor current and installation fault level before selection.
Looking for ABB 1SAM451000R1016? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAM451000R1016 |
| Category | Electrical & controls |
| Ex Operating Instructions | ATEX - Operating instructions for MS165 for potentially explosive areas |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS165-54 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400/690V -Manual Motor Starter MS165/MO165 |
| Product Net Width | 55 mm |
| Product Net Height | 142.65 mm |
| Product Net Depth / Length | 122.1 mm |
| Product Net Weight | 0.97 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 30 kA at 230 V AC; 30 kA at 400 V AC; 20 kA at 500 V AC; 6 kA at 690 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 50 kA at 230 V AC; 50 kA at 400 V AC; 20 kA at 500 V AC; 8 kA at 690 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 810 A |
| Setting Range | 40–54 A |
| Rated Operational Power AC-3 (P e ) | 22 kW at 400 V, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 22 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Rated Operational Current (I e ) | 54 A |
| Rated Operational Current AC-3 (I e ) | 54 A |
| Rated Operational Current AC-3e (I e ) | 54 A |
| Rated Operational Current DC-5 (I e ) | 54 A |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Operating Frequency (f sw ) | 0 ... 415 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 8 kV |
| Rated Insulation Voltage (U i ) | 1000 V |
| Power Loss | at Rated Operating Conditions per Pole 3.84 ... 6.99 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 54 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 35 mm² |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip class | 10 |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What is the current setting range of ABB 1SAM451000R1016?
The ABB MS165-54 has an adjustable overload setting range of 40–54 A and a rated operational current of 54 A. Check that the motor's rated current falls within the setting range and verify the complete application before selecting it.
What protection and operating features does the MS165-54 provide?
It provides motor overload and phase-failure protection, with trip class 10, and short-circuit protection. It also has a disconnect function, lockable rotary handle and fault indication. Confirm suitability for the installation and available fault current before use.
What are the motor power and short-circuit ratings at 400 V?
For three-phase AC-3 operation at 400 V, the MS165-54 is rated 22 kW. Its 400 V AC service breaking capacity Ics is 30 kA and ultimate breaking capacity Icu is 50 kA. Breaking capacity depends on voltage and must be checked against the installation's prospective fault current.
What are the MS165-54 dimensions and terminal type?
The listed dimensions are 55 mm wide, 142.65 mm high and 122.1 mm deep; the unit uses screw terminals. It can be mounted on a suitable DIN rail. Check enclosure clearance and wiring requirements for the installation.