1SAZ421201R1006 — Thermal overload relay
relayPart number: 1SAZ421201R1006
ABB 1SAZ421201R1006 is a TA200DU-200 three-pole thermal overload relay with a 150–200 A adjustable current range and class 10A trip characteristic. It provides motor overload and phase-failure protection and features selectable manual or automatic reset, trip indication, TEST and STOP functions, and temperature compensation.
Looking for ABB 1SAZ421201R1006? This catalogue reference is listed under relay. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAZ421201R1006 |
| Category | Electrical & controls |
| Time-Current Characteristic Curve | Tripping characteristic - Thermal overload relay TA200DU-200, TA200DU-200 V1000 |
| Product Net Width | 104 mm |
| Product Net Height | 151 mm |
| Product Net Depth / Length | 126 mm |
| Product Net Weight | 0.785 kg |
| Setting Range | 150–200 A |
| Rated Operational Voltage | Main circuit 690 V AC; auxiliary circuit 500 V AC or 440 V DC |
| Rated Operational Current (I e ) | 200 A |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Auxiliary Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Number of Poles | 3 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Protected Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Auxiliary Circuit NC 5 A |
| Rated Operational Current AC-15 (I e ) | (120 V) NC 3 A |
| Rated Operational Current DC-13 (I e ) | (125 V) NC 0.25 A |
| Degree of Protection | Housing IP20; main circuit terminals IP00 |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Main Circuit | Hole Diameter > 10 mm² |
| Tightening Torque | Auxiliary Circuit 1 ... 1.3 N·m |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Mounting Position | 1 ... 6 |
| Power Loss | at Rated Operating Conditions per Pole 4.3 ... 7.7 W |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Contact Rating UL/CSA | (NO:) B600 |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1x 4-0000 AWG |
| Published component type | Thermal overload relay |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip Class | 10A |
| Reset Mode | Selectable manual or automatic |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What current range and trip class does ABB 1SAZ421201R1006 have?
The TA200DU-200 has an adjustable current setting range of 150–200 A and a class 10A trip characteristic. Check the motor nameplate and protection requirements before selecting the relay.
What protection does the TA200DU-200 provide?
This three-pole thermal overload relay provides motor overload and phase-failure protection. Short-circuit protection must be selected separately; the relay is not a substitute for a properly rated short-circuit protective device.
Does the TA200DU-200 offer manual and automatic reset?
Yes. The relay has selectable manual or automatic reset, a trip indicator, and TEST and STOP functions. It also has temperature compensation.
How can I check whether this relay will fit my contactor?
The relay connects directly to compatible block contactors; a separate mounting kit is available. Verify the exact contactor model, equipment details and, where applicable, serial number before ordering; compatibility cannot be established from the relay number alone.
What auxiliary contacts are included on the TA200DU-200?
The relay has one normally closed trip contact and one normally open signalling contact. Check the control circuit voltage and contact ratings for the intended application.
Researched on:
Research information may be outdated. Confirm fitment and specifications with our team before ordering.