Technical illustration — ABB 1SAZ431201R1001 — 1SAZ431201R1001 — Thermal overload relay

Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.

ABB

1SAZ431201R1001 — Thermal overload relay

relay

Part number: 1SAZ431201R1001

ABB TF140DU-90 (1SAZ431201R1001) is a three-pole thermal overload relay for motor overload and phase-failure protection. It has an adjustable 66–90 A setting range, class 10A trip characteristic, selectable manual or automatic reset, trip indication, and TEST and STOP functions.

Looking for ABB 1SAZ431201R1001? This catalogue reference is listed under relay. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerABB
Part number1SAZ431201R1001
CategoryElectrical & controls
Time-Current Characteristic CurveTripping characteristic - Thermal overload relay TF140DU-90/TF140DU-90-V1000
Product Net Width89 mm
Product Net Height140 mm
Product Net Depth / Length126 mm
Product Net Weight0.82 kg
Setting Range66–90 A
Rated Operational VoltageMain circuit: 690 V AC, 440 V DC; auxiliary circuit: 500 V AC, 440 V DC
Rated Operational Current (I e )90 A
Rated Frequency (f)Main and auxiliary circuits: DC, 50/60 Hz
Rated Impulse Withstand Voltage (U imp )Main circuit: 8 kV; auxiliary circuit: 6 kV
Rated Insulation Voltage (U i )690 V
Number of Poles3
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (I th )Auxiliary Circuit NC 10 A
Rated Operational Current AC-15 (I e )(120 V) NC 3 A
Rated Operational Current DC-13 (I e )(125 V) NC 0.25 A
Degree of ProtectionIP20
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 16 ... 70 mm²
Tightening TorqueAuxiliary Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm
Mounting Positionany
Power Lossat Rated Operating Conditions per Pole 2.1 W
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 6-2/0 AWG
Published component typeThermal overload relay
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10A
Reset ModeSelectable manual or automatic

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

What current range and trip class does the ABB TF140DU-90 provide?

ABB identifies 1SAZ431201R1001 as the TF140DU-90, with an adjustable setting range of 66–90 A and trip class 10A. Check the motor rated current and starting requirements when selecting the relay.

What protection does the TF140DU-90 provide?

This three-pole thermal overload relay is intended to protect motors against overload and phase failure. The TF140DU documentation also specifies a separate short-circuit protective device; selection must suit the complete installation.

Does the TF140DU-90 support manual and automatic reset?

Yes. Manual or automatic reset can be selected. The relay also has a trip indication and TEST and STOP functions.

What auxiliary contacts does the TF140DU-90 have?

The TF140DU has one normally closed auxiliary contact, 95–96, and one normally open contact, 97–98. Their current ratings depend on voltage and utilization category.

Researched on:

Research information may be outdated. Confirm fitment and specifications with our team before ordering.

Get a quote for this part

Make yourself at home.

Choose your language and delivery destination. Final pricing and shipping are confirmed in your quote.