1SAZ711201R1040 — Thermal overload relay
relayPart number: 1SAZ711201R1040
ABB 1SAZ711201R1040, type T16-7.6, is a thermal overload relay with an adjustable 5.7–7.6 A setting range and class 10 tripping. It provides motor overload protection with phase-loss sensitivity, selectable manual or automatic reset, and normally closed trip and normally open signal contacts. A separate short-circuit protective device is required.
Looking for ABB 1SAZ711201R1040? This catalogue reference is listed under relay. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SAZ711201R1040 |
| Category | Electrical & controls |
| Time-Current Characteristic Curve | Tripping characteristic - Thermal overload relay T16-7.6 |
| Product Net Width | 45 mm |
| Product Net Height | 76.7 mm |
| Product Net Depth / Length | 53.5 mm |
| Product Net Weight | 0.1 kg |
| Setting Range | 5.7–7.6 A |
| Rated Operational Voltage | Auxiliary Circuit 600 V AC/DC |
| Rated Operational Current (I e ) | 7.6 A |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Auxiliary Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Number of Poles | 3P |
| Number of Auxiliary Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Protected Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Auxiliary Circuit NC 6 A |
| Rated Operational Current AC-15 (I e ) | (120 V) NC 3 A |
| Rated Operational Current DC-13 (I e ) | (125 V) NC 0.55 A |
| Degree of Protection | IP20 |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 4 mm² |
| Tightening Torque | Auxiliary Circuit 1 ... 1.2 N·m |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Power Loss | at Rated Operating Conditions per Pole 1.1 ... 2.0 W |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Contact Rating UL/CSA | (NC:) B600 |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 18-12 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-12 AWG |
| Published component type | Thermal overload relay |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip Class | 10 |
| Reset Method | Selectable manual or automatic |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What current range and trip class does ABB 1SAZ711201R1040 have?
The T16-7.6 has an adjustable overload setting range of 5.7–7.6 A and trip class 10. Check the motor nameplate and the complete protection design before selecting the relay.
What protection does the T16-7.6 provide, and does it replace short-circuit protection?
It provides thermal motor overload protection with phase-loss sensitivity. A separate, appropriately selected short-circuit protective device is required.
Does the T16-7.6 have manual and automatic reset?
Yes. Manual or automatic reset can be selected. The relay also has a trip indication, a stop function and one normally closed trip contact and one normally open signal contact.
Can this relay be mounted separately from a contactor?
A DB16 single mounting kit is offered for stand-alone mounting instead of direct contactor mounting. Check the mounting arrangement and the existing contactor model before ordering.