Catalogue reference. Availability, exact specification and OEM or aftermarket supply are confirmed in your quotation.
1SBH103001R8162 — Block Contactor Relay
contactorPart number: 1SBH103001R8162
ABB 1SBH103001R8162, type NSL62E-81, is an eight-pole block contactor relay for switching auxiliary and control circuits. It has six normally open and two normally closed mechanically linked auxiliary contacts, a 24 V DC coil and screw terminals. The low-consumption coil is suitable for direct PLC output control when the output is appropriately rated.
Looking for ABB 1SBH103001R8162? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SBH103001R8162 |
| Category | Electrical & controls |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 100.2 mm |
| Product Net Height | 68 mm |
| Product Net Weight | 0.32 kg |
| Number of Auxiliary Contacts NO | 6 |
| Number of Auxiliary Contacts NC | 2 |
| Rated Operational Voltage | Auxiliary circuit: 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | 10 A at 40 °C, according to IEC 60947-5-1 |
| Rated Operational Current AC-15 (I e ) | 2 A at 500 V |
| Rated Operational Current DC-13 (I e ) | 6 A at 24 V DC (144 W) |
| Rated Short-time Withstand Current Low Voltage (I cw ) | for 0.1 s 140 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U imp ) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U c ) | 24 V DC |
| Power Loss | at 6 A per Pole 0.1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 15 ... 20 ms |
| Mounting on DIN Rail | TH35-7.5 or TH35-15, according to IEC 60715 |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Degree of Protection | Auxiliary and coil terminals: IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m |
| Terminal Type | Screw terminals |
| Product Name | Block Contactor Relay |
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Published component type | Block Contactor Relay |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Coil Consumption | 3 W average pull-in from cold and 3 W average holding |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What coil voltage and polarity does 1SBH103001R8162 require?
The NSL62E-81 has a 24 V DC control coil. Its coil terminals are polarity-sensitive: A1 is positive and A2 is negative.
How many contacts does the NSL62E-81 have?
It has eight auxiliary contacts: six normally open and two normally closed. The auxiliary contact elements are mechanically linked.
Can this relay be controlled directly by a PLC output?
The NSL relay is designed for direct PLC output control and has a 3 W coil consumption at pull-in and holding. Check that the chosen PLC output and supply can drive the coil and observe its polarity.
What load current can the NSL62E-81 switch?
The rating depends on the utilization category and voltage. For example, the listed AC-15 rating is 4 A at 220–240 V, while the DC-13 rating is 6 A at 24 V. Verify the actual load and operating conditions before selection.
How is the 1SBH103001R8162 mounted and how large is it?
The relay is 45 mm wide, 68 mm high and 100.2 mm deep. It can mount on TH35-7.5 or TH35-15 DIN rail and has screw terminals.
Researched on:
Research information may be outdated. Confirm fitment and specifications with our team before ordering.