Part number: 1SBH136001R2222

ABB 1SBH136001R2222, type NFZ22E-22, is a four-pole block contactor relay for auxiliary and control circuits. It has two normally open and two normally closed mechanically linked contacts, an electronic 48–130 V AC/DC coil and built-in surge suppression. The relay uses screw terminals.

Looking for ABB 1SBH136001R2222? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerABB
Part number1SBH136001R2222
CategoryElectrical & controls
Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.31 kg
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles4P
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I th )acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (I e )6 A at 24–127 V; 4 A at 220–240 V; 3 A at 400–440 V; 2 A at 500 V; 2 A at 690 V
Rated Operational Current DC-13 (I e )(24 V) 6 A / 144 W
Rated Short-time Withstand Current Low Voltage (I cw )for 0.1 s 140 A
Rated Insulation Voltage (U i )acc. to IEC 60947-5-1 690 V
Rated Impulse Withstand Voltage (U imp )6 kV
Maximum Electrical Switching FrequencyAC-15: 1200 cycles per hour; DC-13: 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (U c )48–130 V AC, 50/60 Hz; 48–130 V DC
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 Screws Placed Diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Degree of ProtectionAuxiliary and coil terminals: IP20
Tightening TorqueAuxiliary Circuit 1.2 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor Relay
Published component typeBlock Contactor Relay
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Ambient Air TemperatureOperation in free air: −40 to +70 °C; storage: −60 to +80 °C
Contact arrangement2 normally open and 2 normally closed mechanically linked auxiliary contacts

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

What control voltage does the ABB 1SBH136001R2222 coil require?

The NFZ22E-22 coil is rated for 48–130 V AC at 50/60 Hz or 48–130 V DC. A 24 V DC supply is below this particular version’s rated control-voltage range.

How many contacts does the NFZ22E-22 have, and what are they used for?

It has four mechanically linked auxiliary contacts: two normally open and two normally closed. It is a contactor relay intended for switching auxiliary and control circuits.

What are the contact current ratings for this relay?

The rating depends on the load and voltage. Examples are 3 A at 400–440 V under AC-15 and 6 A at 24 V under DC-13. The 16 A free-air thermal current at 40 °C is not a universal switching rating.

Does this contactor relay have built-in surge suppression?

Yes. The NFZ contactor relay has built-in surge suppression. Check the rated coil voltage and the control circuit requirements when selecting it.

What dimensions and terminals should I check before replacing the relay?

The listed net dimensions are 45 mm wide, 86 mm high and 77 mm deep, with screw terminals. Verify the existing part number, coil voltage, contacts, ratings and mounting before selecting a replacement; equipment fitment is not established.