Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.
1SBH136061R2140 — Block Contactor Relay
contactorPart number: 1SBH136061R2140
ABB 1SBH136061R2140, type NFZB40E-21, is a four-pole block contactor relay for auxiliary and control circuit switching. It has four normally open contacts, screw terminals and an electronic coil rated for 24–60 V AC at 50/60 Hz or 20–60 V DC. The relay is designed for rolling-stock control applications; confirm the circuit ratings and equipment requirements before selection.
Looking for ABB 1SBH136061R2140? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SBH136061R2140 |
| Category | Electrical & controls |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 77 mm |
| Product Net Height | 86 mm |
| Product Net Weight | 0.31 kg |
| Number of Auxiliary Contacts NO | 4 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Rated Operational Voltage | Auxiliary circuit: 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | 16 A at 40 °C, according to IEC 60947-5-1 |
| Rated Operational Current AC-15 (I e ) | 6 A at 24–127 V; 4 A at 220–240 V; 3 A at 400–440 V; 2 A at 500 V; 2 A at 690 V |
| Rated Operational Current DC-13 (I e ) | 6 A at 24 V; 2.8 A at 48 V; 1 A at 72 V; 0.55 A at 110 V |
| Rated Short-time Withstand Current Low Voltage (I cw ) | for 0.1 s 140 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-5-1 690 V |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour |
| Maximum Mechanical Switching Frequency | 6000 cycles per hour |
| Rated Control Circuit Voltage (U c ) | 24–60 V AC, 50/60 Hz; 20–60 V DC |
| Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 ms |
| Mounting on DIN Rail | TH35-7.5 or TH35-15, according to IEC 60715 |
| Mounting by Screws (not supplied) | Two M4 screws placed diagonally |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Wire Stripping Length | Control Circuit 10 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1.2 N·m |
| Terminal Type | Screw terminals |
| Product Name | Block Contactor Relay |
| Published component type | Block Contactor Relay |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What coil control voltage does ABB 1SBH136061R2140 accept?
The NFZB40E-21 is rated for 24–60 V AC at 50/60 Hz or 20–60 V DC. Check the actual control supply and its fluctuations against the applicable limits before selecting it; the coil rating is not the contact switching voltage.
How many contacts does the NFZB40E-21 have, and are they normally open?
It has four normally open contacts and no normally closed contacts in the base relay. The contact configuration should be checked against the circuit requirements before replacement.
What current can the 1SBH136061R2140 contacts switch?
The permissible operational current depends on voltage and utilization category. For example, the AC-15 rating is 4 A at 220–240 V AC and 2 A at 500 V AC; the DC-13 rating is 6 A at 24 V DC and 2.8 A at 48 V DC. Do not use the 16 A thermal current as a universal switching rating.
How is the NFZB40E-21 mounted and connected?
It uses screw terminals and can be mounted on TH35-7.5 or TH35-15 DIN rail, or with two diagonally placed M4 screws, which are not supplied. Check the available panel space and connection requirements before ordering.
Researched on: