1SBH137001R1340 — Block Contactor Relay
contactorPart number: 1SBH137001R1340
ABB 1SBH137001R1340, type NF40E-13, is a four-pole contactor relay for auxiliary and control circuits. It has four normally open contacts, a 100–250 V AC 50/60 Hz or DC control coil, screw terminals and built-in surge protection.
Looking for ABB 1SBH137001R1340? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SBH137001R1340 |
| Category | Electrical & controls |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 77 mm |
| Product Net Height | 86 mm |
| Product Net Weight | 0.27 kg |
| Number of Auxiliary Contacts NO | 4 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (I e ) | 6 A at 24/127 V; 4 A at 220/240 V; 3 A at 400/440 V; 2 A at 500 V or 690 V |
| Rated Operational Current DC-13 (I e ) | 6 A / 144 W at 24 V; 2.8 A / 134 W at 48 V; 1 A / 72 W at 72 V; 0.55 A / 60 W at 110 V; 0.55 A / 69 W at 125 V; 0.27 A / 60 W at 220 V; 0.27 A / 68 W at 250 V; 0.15 A / 60 W at 400 V; 0.13 A / 65 W at 500 V; 0.1 A / 60 W at 600 V |
| Rated Short-time Withstand Current Low Voltage (I cw ) | 140 A for 0.1 s; 100 A for 1 s |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-5-1 690 V |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Maximum Electrical Switching Frequency | AC-15: 1200 cycles per hour; DC-13: 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 6000 cycles per hour |
| Rated Control Circuit Voltage (U c ) | 100–250 V AC, 50/60 Hz; 100–250 V DC |
| Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 ms |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Wire Stripping Length | Auxiliary Circuit 10 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1.2 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor Relay |
| Published component type | Block Contactor Relay |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Ambient Air Temperature | Operation in free air: −40 to +70 °C; storage: −60 to +80 °C |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What control voltage does the ABB NF40E-13 coil accept?
The control circuit is rated for 100–250 V AC at 50/60 Hz or 100–250 V DC. Check the actual control supply before selecting the relay.
How many normally open and normally closed contacts does 1SBH137001R1340 have?
This four-pole contactor relay has four normally open auxiliary contacts and no normally closed auxiliary contacts.
What are the contact current ratings for the NF40E-13?
The rating depends on utilization category and voltage: AC-15 is 4 A at 220–240 V or 2 A at 500 V; DC-13 is 6 A at 24 V. The 16 A free-air thermal current is not a universal switching rating.
Does the NF40E-13 require a separate coil surge suppressor?
The NF contactor relay incorporates surge protection; the product information states that an additional surge suppressor is not required.
Researched on: