ABB 1SBH137001R1362, type NF62E-13, is an eight-pole block contactor relay for switching auxiliary and control circuits. It has six normally open and two normally closed contacts, a 100–250 V AC/DC electronic control coil, built-in surge suppression and screw terminals.
Looking for ABB 1SBH137001R1362? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SBH137001R1362 |
| Category | Electrical & controls |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 110.5 mm |
| Product Net Height | 86 mm |
| Product Net Weight | 0.32 kg |
| Number of Auxiliary Contacts NO | 6 |
| Number of Auxiliary Contacts NC | 2 |
| Number of Poles | 8 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (I e ) | (500 V) 2 A |
| Rated Operational Current DC-13 (I e ) | (24 V) 6 A / 144 W |
| Rated Short-time Withstand Current Low Voltage (I cw ) | for 0.1 s 140 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-5-1 690 V |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour |
| Maximum Mechanical Switching Frequency | 6000 cycles per hour |
| Rated Control Circuit Voltage (U c ) | 100–250 V AC, 50/60 Hz; 100–250 V DC |
| Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 ms |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Wire Stripping Length | Auxiliary Circuit 10 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1.2 N·m |
| Terminal Type | Screw terminals |
| Product Name | Block Contactor Relay |
| Published component type | Block Contactor Relay |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Mounting method | DIN rail or screw mounting |
| Surge suppression | Built-in |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What control voltage does the ABB NF62E-13 coil accept?
The 1SBH137001R1362 coil is rated for 100–250 V AC at 50/60 Hz or 100–250 V DC. This is the control supply range, not the contact load rating.
How many contacts does 1SBH137001R1362 have?
It is an eight-pole contactor relay with six normally open and two normally closed auxiliary contacts.
How is the ABB NF62E-13 mounted and connected?
It supports DIN-rail or screw mounting and uses screw terminals. Its listed dimensions are 45 mm wide, 86 mm high and 110.5 mm deep.
Does the NF62E-13 need a separate coil surge suppressor?
The relay has built-in surge suppression; the product information says an additional suppression element is not required.
Researched on:
Research information may be outdated. Confirm fitment and specifications with our team before ordering.