Technical illustration — ABB 1SBH137001R1422 — 1SBH137001R1422 — Block Contactor Relay

Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.

ABB

1SBH137001R1422 — Block Contactor Relay

contactor

Part number: 1SBH137001R1422

ABB 1SBH137001R1422 is an NF22E-14 four-pole contactor relay for auxiliary and control circuits. It has two normally open and two normally closed mechanically linked contacts, a 250–500 V AC 50/60 Hz or DC electronic control coil, built-in surge protection and screw terminals.

Looking for ABB 1SBH137001R1422? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerABB
Part number1SBH137001R1422
CategoryElectrical & controls
Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.31 kg
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles4P
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I th )acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (I e )6 A at 24–127 V; 4 A at 220–240 V; 3 A at 400–440 V; 2 A at 500 V; 2 A at 690 V
Rated Operational Current DC-13 (I e )6 A / 144 W at 24 V DC; 2.8 A / 134 W at 48 V DC; 1 A / 72 W at 72 V DC; 0.55 A / 60 W at 110 V DC; 0.55 A / 69 W at 125 V DC; 0.27 A / 60 W at 220 V DC; 0.27 A / 68 W at 250 V DC; 0.15 A / 60 W at 400 V DC; 0.13 A / 65 W at 500 V DC; 0.1 A / 60 W at 600 V DC
Rated Short-time Withstand Current Low Voltage (I cw )for 0.1 s 140 A
Rated Insulation Voltage (U i )acc. to IEC 60947-5-1 690 V
Rated Impulse Withstand Voltage (U imp )6 kV
Maximum Electrical Switching FrequencyAC-15: 1,200 cycles per hour; DC-13: 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (U c )250–500 V AC, 50/60 Hz; 250–500 V DC
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms
Mounting on DIN RailTH35-7.5 (35 × 7.5 mm) or TH35-15 (35 × 15 mm), according to IEC 60715
Mounting by Screws (not supplied)2 x M4 Screws Placed Diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Tightening TorqueAuxiliary Circuit 1.2 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor Relay
Published component typeBlock Contactor Relay
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Surge ProtectionBuilt-in coil surge protection
Contact Configuration2 normally open and 2 normally closed mechanically linked auxiliary contacts
Ambient Operating Temperature−40 to +70 °C in free air near the contactor

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

What control voltage does ABB 1SBH137001R1422 require?

The NF22E-14 coil is rated for 250–500 V AC at 50/60 Hz or 250–500 V DC. This is the control supply rating, not the contact switching voltage; check the actual control supply before ordering.

How many contacts does the NF22E-14 relay have?

It has four mechanically linked auxiliary contacts: two normally open and two normally closed. It is intended for switching auxiliary and control circuits.

What current can the NF22E-14 contacts switch?

The rating depends on utilization category and voltage. For AC-15 it is 4 A at 220–240 V and 3 A at 400–440 V; for DC-13 it is 6 A at 24 V DC and 0.27 A at 220 V DC. Do not use the 16 A thermal rating as a universal switching rating.

How can the 1SBH137001R1422 contactor relay be mounted?

It fits 35 × 7.5 mm or 35 × 15 mm DIN rail, or can be fixed with two diagonally placed M4 screws. ABB specifies that the screws are not supplied.

Does the NF22E-14 require an external coil surge suppressor?

ABB specifies built-in surge protection for NF contactor relays and says an additional surge suppressor is not required for the coil.