1SBH141001R8822 — N22E 230-240V 50Hz / 240-260V 60Hz Contactor Relay
contactorPart number: 1SBH141001R8822
ABB 1SBH141001R8822 is an N22E four-pole contactor relay for switching auxiliary and control circuits. It has two normally open and two normally closed contacts, screw terminals, and an AC coil rated 230–240 V at 50 Hz or 240–260 V at 60 Hz. Verify the control supply and load ratings for the intended installation.
Looking for ABB 1SBH141001R8822? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SBH141001R8822 |
| Category | Electrical & controls |
| Published component description | N22E 230-240V 50Hz / 240-260V 60Hz Contactor Relay |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Contact configuration | 2 normally open + 2 normally closed |
| Rated control circuit voltage | 230–240 V AC at 50 Hz; 240–260 V AC at 60 Hz |
| Terminal type | Screw terminals |
| Conventional free-air thermal current | 16 A at 40 °C, according to IEC 60947-5-1 |
| Rated operational current, AC-15 | 4 A at 220–240 V |
| Dimensions (width × height × depth) | 44 × 74 × 74 mm |
| Net weight | 0.34 kg |
| Coil terminal protection | IP20 |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What coil voltage does ABB 1SBH141001R8822 require?
This N22E variant has an AC control coil rated 230–240 V at 50 Hz or 240–260 V at 60 Hz. Check the control supply and frequency before selection; an N22E with a different coil rating is not automatically interchangeable.
How many contacts does the N22E contactor relay have?
It has four auxiliary contacts: two normally open (NO) and two normally closed (NC). It is intended for switching auxiliary and control circuits.
What current can the contacts switch at 230 V AC?
The stated AC-15 operational current is 4 A at 220–240 V. The 16 A free-air thermal current at 40 °C is a different rating and should not be treated as the switching rating for every load. Check the utilization category and load before selection.
How can I check whether this relay will replace the one in my equipment?
Compare the complete part number, coil voltage and frequency, contact arrangement, switching ratings, dimensions and terminals with the existing relay. Equipment fitment is not established; provide the equipment model and serial number and a photo of the existing nameplate for verification.
Researched on: