Technical illustration — ABB 1SBL103001R8101 — 1SBL103001R8101 — Block Contactor

Technical illustration. Representative component image; exact configuration and appearance may vary. Images are for reference only. The supplied part’s appearance may differ.

ABB

1SBL103001R8101 — Block Contactor

contactor

Part number: 1SBL103001R8101

ABB 1SBL103001R8101 (ASL09-30-01-81) is a three-pole block contactor with a 24 V DC control coil, three normally open main contacts and one normally closed auxiliary contact. It has screw terminals and is rated 9 A for AC-3 duty at 380–400 V and 4 kW at 400 V. The contactor is intended for three-phase motor and power-circuit control.

Looking for ABB 1SBL103001R8101? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerABB
Part number1SBL103001R8101
CategoryElectrical & controls
Product Net Width45 mm
Product Net Depth / Length72.5 mm
Product Net Height68 mm
Product Net Weight0.28 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain and auxiliary circuits: 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I th )acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 22 A
Rated Operational Current AC-1 (I e )22 A at 690 V, 40 °C
Rated Operational Current AC-3 (I e )9 A at 380–400 V, 60 °C
Rated Operational Current AC-15 (I e )(500 V) NC 2
Rated Operational Current DC-13 (I e )(24 V) 6 A / 144 W
Rated Operational Power AC-3 (P e )4 kW at 400 V
Rated Short-time Withstand Current Low Voltage (I cw )at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A
Rated Insulation Voltage (U i )acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (U imp )Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (U c )DC operation: 24 V
Power Lossat Rated Operating Conditions AC-1 per Pole 1 W
Operate TimeBetween Coil De-energization and NC Contact Closing 15 ... 20 ms
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Published component typeBlock Contactor
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Terminal TypeScrew terminals
Degree of ProtectionIP20 at main, auxiliary and coil terminals

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

What coil voltage does ABB 1SBL103001R8101 require?

It has a 24 V DC control coil. The coil is polarity-sensitive: A1 is positive and A2 is negative. The 50/60 Hz main-circuit rating is not an AC coil rating.

What are the motor and load ratings of the ASL09-30-01-81?

For AC-3 motor duty it is rated 9 A at 380–400 V and 60 °C, with a 4 kW rating at 400 V. Its AC-1 rating is 22 A at 690 V and 40 °C. Ratings depend on voltage, duty and ambient temperature.

How many main and auxiliary contacts does this contactor have?

The contactor has three normally open main contacts and one built-in normally closed auxiliary contact. It has no normally closed main contacts or normally open auxiliary contacts.

Can the 24 V DC coil be controlled directly by a PLC output?

The low-consumption DC coil is described as suitable for direct PLC output control, subject to the output meeting the coil requirements. Confirm output voltage, current capacity and polarity for the specific controller.

Will this contactor fit my existing control panel?

The contactor measures 45 mm wide, 68 mm high and 72.5 mm deep, with screw terminals. Dimensions alone do not establish interchangeability; provide the equipment model, serial number, existing part number and control-circuit details for verification.

Researched on:

Research information may be outdated. Confirm fitment and specifications with our team before ordering.

Get a quote for this part

Make yourself at home.

Choose your language and delivery destination. Final pricing and shipping are confirmed in your quote.