1SBL103001R8110 — Block Contactor
contactorPart number: 1SBL103001R8110
ABB 1SBL103001R8110 (ASL09-30-10-81) is a three-pole block contactor with a 24 V DC control coil, three normally open main contacts and one built-in normally open auxiliary contact. Its AC-3 rating is 9 A at 380–400 V and 4 kW at 400 V. It uses screw terminals and is intended for motor and power-circuit control.
Looking for ABB 1SBL103001R8110? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SBL103001R8110 |
| Category | Electrical & controls |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 72.5 mm |
| Product Net Height | 68 mm |
| Product Net Weight | 0.28 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 22 A |
| Rated Operational Current AC-1 (I e ) | (690 V) 40 °C 22 A |
| Rated Operational Current AC-3 (I e ) | 9 A at 380–400 V and 60 °C; 9 A at 415 V and 60 °C; 8 A at 440–500 V and 60 °C; 5 A at 690 V and 60 °C |
| Rated Operational Current AC-15 (I e ) | (500 V) NC 2 |
| Rated Operational Current DC-13 (I e ) | (24 V) 6 A / 144 W |
| Rated Operational Power AC-3 (P e ) | 4 kW at 400 V; 2.2 kW at 220–240 V |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U imp ) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U c ) | 24 V DC |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 15 ... 20 ms |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Published component type | Block Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Extended product type | ASL09-30-10-81 |
| Terminal Type | Screw terminals |
| Mounting on DIN Rail | TH35-7.5 or TH35-15; 35 mm rail |
| Degree of Protection | IP20 at main, auxiliary and coil terminals |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What control voltage does the ABB 1SBL103001R8110 coil require?
The ASL09-30-10-81 has a 24 V DC control coil, not a 24 V AC coil. Coil polarity matters: A1 is positive and A2 is negative.
What motor and current ratings apply to the ASL09-30-10-81?
For AC-3 motor duty it is rated 9 A at 380–400 V and 60 °C, and 4 kW at 400 V. For AC-1 duty it is rated 22 A at 690 V and 40 °C. Check the actual load and operating conditions before selection.
How many main and auxiliary contacts does 1SBL103001R8110 have?
It has three normally open main contacts and one built-in normally open auxiliary contact. There are no built-in normally closed main or auxiliary contacts.
Can a PLC output control the ASL09-30-10-81 contactor directly?
The low-consumption 24 V DC coil is described as suitable for direct PLC output control. Verify the particular output and power supply ratings and observe the coil polarity before specifying the circuit.
What mounting rail and terminal type does this contactor use?
It uses screw terminals and can mount on TH35-7.5 or TH35-15 DIN rail. Its body dimensions are 45 mm wide, 68 mm high and 72.5 mm deep.