1SBL111001R2010 — Block Contactor
contactorPart number: 1SBL111001R2010
ABB 1SBL111001R2010 (AS12-30-10-20) is a three-pole block contactor for controlling three-phase motors and power circuits. It has a 24 V AC, 50/60 Hz control coil, three normally open main contacts and one normally open auxiliary contact. Its AC-3 motor rating at 400 V is 12 A and 5.5 kW.
Looking for ABB 1SBL111001R2010? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 1SBL111001R2010 |
| Category | Electrical & controls |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 72.5 mm |
| Product Net Height | 68 mm |
| Product Net Weight | 0.22 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 25 A |
| Rated Operational Current AC-1 (I e ) | (690 V) 40 °C 24 A |
| Rated Operational Current AC-3 (I e ) | (415 V) 60 °C 12 A |
| Rated Operational Current AC-15 (I e ) | (500 V) NC 2 |
| Rated Operational Current DC-13 (I e ) | (24 V) 6 A / 144 W |
| Rated Operational Power AC-3 (P e ) | 5.5 kW at 400 V |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 124 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U imp ) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U c ) | 50 Hz 24 V |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1.2 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 22 ms |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Published component type | Block Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Rated control circuit voltage (Uc) | 24 V AC, 50/60 Hz |
| Rated operational current AC-3 (400 V) | 12 A |
| Rated operational current AC-1 (400 V) | 24 A |
| Main circuit connection | Screw connection |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What coil voltage does ABB 1SBL111001R2010 require?
The AS12-30-10-20 has a 24 V AC control coil rated for both 50 Hz and 60 Hz. Match the control supply to the coil rating; the motor supply voltage is a separate consideration.
What are the motor and current ratings of the AS12-30-10-20?
At 400 V, the contactor is rated 12 A in AC-3 duty and 5.5 kW for motor operation. The AC-1 current rating at 400 V is 24 A. Select the rating for the actual load and duty.
How many main and auxiliary contacts does this contactor have?
It has three normally open main contacts and one built-in normally open auxiliary contact; there are no normally closed main or auxiliary contacts built in.
What are the dimensions and main terminal type?
The contactor measures 45 mm wide, 68 mm high and 72.5 mm deep. Its main circuit uses screw connections.
Can this contactor replace the unit in my machine?
Compatibility cannot be established from the part number alone. Check the existing contactor code, 24 V AC coil supply, contact arrangement, load ratings and mounting. Provide the equipment model and serial number for verification.
Researched on: