1SBL281074R8010No product image available

Catalogue reference. Availability, exact specification and OEM or aftermarket supply are confirmed in your quotation.

ABB

1SBL281074R8010 — Block Contactor

contactor

Part number: 1SBL281074R8010

1SBL281074R8010 — Block Contactor — ABB reference 1SBL281074R8010. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Looking for ABB 1SBL281074R8010? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerABB
Part number1SBL281074R8010
CategoryElectrical & controls
Product Net Width54 mm
Product Net Depth / Length90 mm
Product Net Height108.3 mm
Product Net Weight0.667 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC0
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I th )acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A
Rated Operational Current AC-1 (I e )(220 / 240 V) 55 °C 55 A
Rated Operational Current AC-3 (I e )(415 V) 55 °C 32 A
Rated Operational Current AC-15 (I e )(500 V) NC 2
Rated Operational Current DC-13 (I e )(24 V) 6 A / 144 W
Rated Operational Power AC-3 (P e )(415 V) 15 kW
Rated Short-time Withstand Current Low Voltage (I cw )at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A
Rated Insulation Voltage (U i )acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (U imp )Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (U c )50 Hz 220 ... 230 V
Power Lossat Rated Operating Conditions AC-1 per Pole 2.5 W
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 14 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Tightening TorqueAuxiliary Circuit 1 N·m
Terminal TypeScrew Terminals
Published component typeBlock Contactor
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

Research is not yet available for this part in English. Ask our team for help.

Get a quote for this part

Make yourself at home.

Choose your language and delivery destination. Final pricing and shipping are confirmed in your quote.