Representative component image—not a photograph of this exact brand or part number. Confirm the specification; the supplied part may look different.
2CSR275151R1104 — Earth leakage circuit breaker
Electrical & controlsPart number: 2CSR275151R1104
2CSR275151R1104 — Earth leakage circuit breaker — ABB reference 2CSR275151R1104. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Looking for ABB 2CSR275151R1104? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | ABB |
|---|---|
| Part number | 2CSR275151R1104 |
| Category | Electrical & controls |
| Sustainable Material Content in Packaging (wt. %) | Recycled Cardboard - 96.89 % |
| Type of Residual Current | Type A |
| Maximum Operating Voltage | 264 V |
| Test Voltage (Ut) | 195 … 264 V |
| Dielectric Test Voltage | 2 kV |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 15 kA |
| Rated Residual Breaking Capacity (IΔm) | 10 kA |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 7.5 kA |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (I cs ) | 7.5 kA |
| Maximum Surge Current | 0.25 kA |
| Power Supply Connection | Bottom |
| Number of Protected Poles | 1 |
| Number of Poles | 1P+N |
| Operating Characteristic | Instantaneous |
| Position of Neutral Terminals | Right |
| Tightening Torque | Top 1.2 N·m |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Connecting Capacity | Busbar 10 mm² |
| Wire Stripping Length | Top 11 mm |
| Terminal Type | Screw Terminals |
| Short-Circuit Current Rating (SCCR) | 0.03 A |
| Rated Operational Voltage | acc. to IEC 60898-1 240 V |
| Rated Insulation Voltage (U i ) | acc. to IEC/EN 60664-1 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (I n ) | 10 A |
| Rated Residual Current | 30 mA |
| Rated Short-Circuit Capacity | 10 kA |
| Published component type | Earth leakage circuit breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
Research is not yet available for this part in English. Ask our team for help.
Get a quote for this part