Catalogue reference. Availability, exact specification and OEM or aftermarket supply are confirmed in your quotation.
KFD2-STC5-EX2 — Pepperl+Fuchs KFD2 Signal Conditioner (P/N: KFD2-STC5-EX2). K-System isolated barrier with galvanic isolation, ATEX/IECEx certification for 4-20mA, HART,…
Sensors & automationPart number: KFD2-STC5-EX2
Pepperl+Fuchs KFD2-STC5-Ex2 is a two-channel isolated barrier and SMART transmitter power supply for intrinsic safety applications. It accepts 4–20 mA signals from 2-wire and 3-wire SMART transmitters or 2-wire SMART current sources and provides current-sink or current-source outputs. It supports HART signal transmission and mounts on a 35 mm DIN rail with screw terminals.
Looking for Pepperl+Fuchs KFD2-STC5-EX2? This catalogue reference is listed under Sensors & automation. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | Pepperl+Fuchs |
|---|---|
| Part number | KFD2-STC5-EX2 |
| Category | Sensors & automation |
| Published description | Two-channel isolated barrier for 4–20 mA SMART transmitter signals, with HART signal transmission, galvanic isolation, DIN-rail mounting and screw terminals. |
| Reference status | Published catalogue reference; confirm specification and fitment before ordering |
| Availability | On request |
| Channels | 2 |
| Field input | 4–20 mA; 2-wire and 3-wire SMART transmitters or 2-wire SMART current sources |
| Control output | 4–20 mA, current sink or current source |
| Supply voltage | 18–30 V DC; Power Rail or terminals |
| Output load | 0–600 Ω |
| Available transmitter voltage | At least 16 V at 20 mA; at least 20 V at 4 mA, at terminals 1 and 3 or 4 and 6 |
| Power consumption | Maximum 2.6 W at maximum load |
| Ambient temperature | −20 to 60 °C; up to 70 °C with mounting conditions specified in the manual |
| Protection degree | IP20 |
| Terminal type | Screw terminals with test points |
| Mounting | 35 mm DIN rail |
| Dimensions | 20 × 124 × 115 mm (W × H × D) |
| Mass | Approximately 200 g |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
What types of input does the KFD2-STC5-Ex2 accept?
It has two channels for 4–20 mA analog signals from 2-wire or 3-wire SMART transmitters or 2-wire SMART current sources. Check the transmitter and loop parameters against the exact device data before selection.
Does the KFD2-STC5-Ex2 pass HART signals?
Yes. This barrier supports HART signal transmission alongside the analog current signal. Check the complete loop and communicator requirements before installation.
Can the outputs be used with sinking and sourcing control inputs?
Yes. The two-channel barrier supports current-sink and current-source output modes. In source mode the barrier powers the output loop; in sink mode the loop requires external power. Verify the control input and wiring against the manufacturer’s diagram.
What supply voltage and mounting does the KFD2-STC5-Ex2 require?
The supply range is 18–30 V DC, connected via the Power Rail or supply terminals. The housing mounts on a 35 mm DIN rail and uses screw terminals.
Is the KFD2-STC5-Ex2 suitable for hazardous-area circuits?
It is an isolated barrier intended for intrinsic safety applications. Suitability depends on the installation zone, field device, entity parameters and applicable documentation; verify the complete circuit and the exact unit and serial number before use.
Researched on: