Representative component image—not a photograph of this exact brand or part number. Confirm the specification; the supplied part may look different.
A9D77425 — Residual current breaker with overcurrent protection (RCBO)
Electrical & controlsPart number: A9D77425
A9D77425 — Residual current breaker with overcurrent protection (RCBO) — Schneider Electric reference A9D77425. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Looking for Schneider Electric A9D77425? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | Schneider Electric |
|---|---|
| Part number | A9D77425 |
| Category | Electrical & controls |
| Range | Acti9 |
| product name | Acti9 iC60 RCBO |
| Product or component type | Residual current breaker with overcurrent protection (RCBO) |
| Poles description | 4P |
| Number of protected poles | 4 |
| [In] rated current | 25 A |
| Network frequency | 50 Hz |
| [Ue] rated operational voltage | 380...415 V AC 50 Hz |
| Residual current tripping technology | Voltage independent |
| Earth-leakage protection time delay | Instantaneous |
| Earth-leakage protection class | Type A-SI (Super Immunised) |
| Breaking capacity | 6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2 |
| [Ics] rated service breaking capacity | 6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA 100 % x Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2 |
| Rated breaking and making capacity | Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
| [Ui] rated insulation voltage | 500 V AC 50 Hz |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Surge current | 3000 A |
| Local signalling | ON, OFF, fault trip |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Connection pitch | 9 mm between poles |
| Height | 86 mm |
| Width | 72 mm |
| Depth | 78 mm |
| Product weight | 423 g |
| Connections - terminals | Tunnel type terminal top or bottom 1…35 mm² rigid Tunnel type terminal top or bottom 1…25 mm² flexible Tunnel type terminal top or bottom 1…25 mm² flexible with ferrule |
| Wire stripping length | 12 mm for top or bottom connection |
| Tightening torque | 2 N.m |
| Published component type | Residual current breaker with overcurrent protection (RCBO) |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
Research is not yet available for this part in English. Ask our team for help.
Get a quote for this part