Technical specifications
| Manufacturer | Schneider Electric |
|---|---|
| Part number | ABLM1A12010 |
| Category | Electrical & controls |
| Range of Product | Modicon Power Supply |
| Product or Component Type | Power supply |
| Power supply type | Regulated switch mode |
| Enclosure Material | Plastic |
| Nominal input voltage | 100...240 V AC single phase 100...240 V AC phase to phase |
| Kw Rating | 12 W |
| Output voltage | 12 V DC |
| Power supply output current | 1 A |
| Efficiency at full load | 90...264 V AC |
| Nominal network frequency | 50…60 Hz |
| Maximum leakage current | 0.25 mA 240 V AC |
| Input protection type | Integrated fuse (not interchangeable) 3.15 A External protection (recommended) 20 A Curve B External protection (recommended) 20 A Curve C External protection (recommended) 2 A Curve B External protection (recommended) 2 A Curve C |
| Inrush current | 15 A 115 V 30 A 230 V |
| Power factor | 0.51 at 115 V AC 0.40 at 230 V AC |
| Efficiency | 80 % 115 V AC 80 % 230 V AC |
| Power dissipation in W | 3 W |
| Current consumption | < 0.4 A 115 V AC < 0.25 A 230 V AC |
| Output protection type | Against overload and short-circuits, protection technology: automatic reset Against over temperature, protection technology: manual reset Against overvoltage, protection technology: manual reset |
| Connections - terminals | Screw connection 0.5...1.5 mm², AWG 20...AWG 16) without wire end ferrule input/output Screw connection 0.5...1 mm², AWG 20...AWG 18) with wire end ferrule input/output |
| Depth | 2.2 in (55.6 mm) |
| Height | 3.6 in (91 mm) |
| Width | 0.7 in (18 mm) |
| Product Weight | 0.223 lb(US) (0.101 kg) |
| Output coupling | Serial |
| Mounting support | Top hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 Double-profile DIN rail panel mounting |
| Supply | SELV IEC 60950-1 SELV IEC 60204-1 SELV IEC 60364-4-41 |
| Overvoltage category | II |
| Published component type | Power supply |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.