Representative component image—not a photograph of this exact brand or part number. Confirm the specification; the supplied part may look different.
GV2RT05 — Motor circuit breaker
Electrical & controlsPart number: GV2RT05
GV2RT05 — Motor circuit breaker — Schneider Electric reference GV2RT05. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Looking for Schneider Electric GV2RT05? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | Schneider Electric |
|---|---|
| Part number | GV2RT05 |
| Category | Electrical & controls |
| Range | TeSys Deca |
| product name | TeSys GV2 |
| Product or Component Type | Motor circuit breaker |
| Poles description | 3P |
| Network frequency | 50/60 Hz IEC 60947-2 |
| Motor power kW | 0.09 kW 220/230 V AC 50/60 Hz motor protection high peak current 0.12 kW 220/230 V AC 50/60 Hz motor protection high peak current 0.25 kW 400/415 V AC 50/60 Hz motor protection high peak current 0.37 kW 400/415 V AC 50/60 Hz motor protection high peak current 0.25 kW 440 V AC 50/60 Hz motor protection high peak current 0.37 kW 440 V AC 50/60 Hz motor protection high peak current 0.37 kW 500 V AC 50/60 Hz motor protection high peak current 0.55 kW 690 V AC 50/60 Hz motor protection high peak current 0.63 kW 440 V AC 50/60 Hz transformer protection 0.63 kW 500 V AC 50/60 Hz transformer protection 1 kW 690 V AC 50/60 Hz transformer protection |
| Breaking capacity | 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2 |
| Line Rated Current | 1 A |
| Thermal protection adjustment range | 0.63…1 A IEC 60947-2 |
| Magnetic tripping current | 22 A |
| [Ith] conventional free air thermal current | 1 A IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV IEC 60947-2 |
| Power dissipation per pole | 2.5 W |
| Tightening torque | 15.05 lbf.in (1.7 N.m) screw clamp terminal |
| Mounting position | Horizontal Vertical |
| Width | 1.8 in (45 mm) |
| Height | 3.5 in (89 mm) |
| Depth | 3.09 in (78.5 mm) |
| Published component type | Motor circuit breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
Research is not yet available for this part in English. Ask our team for help.
Get a quote for this part