Representative component image—not a photograph of this exact brand or part number. Confirm the specification; the supplied part may look different.
LC1BP33M22 — Contactor
contactorPart number: LC1BP33M22
LC1BP33M22 — Contactor — Schneider Electric reference LC1BP33M22. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Looking for Schneider Electric LC1BP33M22? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | Schneider Electric |
|---|---|
| Part number | LC1BP33M22 |
| Category | Electrical & controls |
| Range | TeSys |
| product name | TeSys B |
| Product or Component Type | Contactor |
| Poles description | 3P |
| [Ie] rated operational current | 2000 A (at <104 °F (40 °C)) AC AC-1 for power circuit 1500 A (at <131 °F (55 °C)) AC AC-3 for power circuit |
| Motor power kW | 425 kW at 220...230 V AC 50/60 Hz (AC-3) 670 kW at 1000 V AC 50/60 Hz (AC-3) 700 kW at 500 V AC 50/60 Hz (AC-3) 750 kW at 380...400 V AC 50/60 Hz (AC-3) 750 kW at 660...690 V AC 50/60 Hz (AC-3) 800 kW at 415 V AC 50/60 Hz (AC-3) 800 kW at 440 V AC 50/60 Hz (AC-3) 220 kW at 400 V AC 50/60 Hz (AC-4) |
| [Uc] control circuit voltage | 220 V AC 50...400 Hz |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc at 50...400 Hz Drop-out: 0.35...0.5 Uc at 50...400 Hz |
| [Ui] rated insulation voltage | 1000 V - power circuit IEC 60158-1 1000 V - power circuit IEC 60947-4 1500 V - power circuit VDE 0110 group C |
| Mounting Mode | Fixed |
| Mounting Support | Notched mounting rails Bar support bracket |
| Connections - terminals | Power circuit bars 3 x 100 x 5 mm |
| Tightening torque | Power circuit 309.8 lbf.in (35 N.m) bars |
| [Ue] rated operational voltage | Power circuit <= 1000 V AC 50/60 Hz |
| [Ith] conventional free air thermal current | 2000 A (at 104 °F (40 °C)) for power circuit |
| Irms rated making capacity | 15000 A at 1000 V AC for power circuit conforming to IEC 60158-1 15000 A at 1000 V AC for power circuit conforming to IEC 60947-4 |
| Rated breaking capacity | 12000 A at 500 V for power circuit conforming to IEC 60158-1 12000 A at 500 V for power circuit conforming to IEC 60947-4 15000 A at 440 V for power circuit conforming to IEC 60158-1 15000 A at 440 V for power circuit conforming to IEC 60947-4 5000 A at 1000 V for power circuit conforming to IEC 60158-1 5000 A at 1000 V for power circuit conforming to IEC 60947-4 9000 A at 660...690 V for power circuit conforming to IEC 60158-1 9000 A at 660...690 V for power circuit conforming to IEC 60947-4 |
| Associated fuse rating | 1600 A aM at <= 440 V for power circuit 2000 A gI at <= 440 V for power circuit |
| Average impedance | 0.13 mOhm - Ith 2000 A 50 Hz for power circuit |
| Power dissipation per pole | 290 W AC-3 - Ith 2000 A 520 W AC-1 - Ith 2000 A |
| Inrush power in VA | 1300 VA |
| Hold-in power consumption in VA | 31 VA 50/60 Hz |
| Operating time | 100...150 ms closing 50...100 ms opening |
| Maximum operating rate | 120 cyc/h 131 °F (55 °C) |
| Height | 19.3 in (490 mm) |
| Width | 31.1 in (790 mm) |
| Depth | 18.7 in (475 mm) |
| Product Weight | 207.2 lb(US) (94 kg) |
| Published component type | Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions