Representative component image—not a photograph of this exact brand or part number. Confirm the specification; the supplied part may look different.
LC1F1700U7 — Contactor
contactorPart number: LC1F1700U7
LC1F1700U7 — Contactor — Schneider Electric reference LC1F1700U7. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Looking for Schneider Electric LC1F1700U7? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | Schneider Electric |
|---|---|
| Part number | LC1F1700U7 |
| Category | Electrical & controls |
| Range | TeSys |
| Range of product | TeSys F |
| Product or component type | Contactor |
| Poles description | 3P |
| [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
| [Uc] control circuit voltage | 240 V AC 40...400 Hz |
| [Ie] rated operational current | 1700 A (at <40 °C) AC AC-1 |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ith] conventional free air thermal current | 1700 A (at 40 °C) |
| Rated breaking capacity | 2550 A conforming to IEC 60947-4-1 |
| [Icw] rated short-time withstand current | 10000 A 40 °C - 10 s 7500 A 40 °C - 30 s 5500 A 40 °C - 1 min 4200 A 40 °C - 3 min 3000 A 40 °C - 10 min |
| Associated fuse rating | 1600 A gG at <= 440 V |
| Average impedance | 0.1 mOhm - Ith 1700 A 50 Hz |
| [Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C 1000 V conforming to UL 60947-4-1 |
| Power dissipation per pole | 200 W AC-1 |
| Overvoltage category | III |
| power pole contact composition | 3 NO |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C) |
| Inrush power in VA | 2200 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
| Hold-in power consumption in VA | 36 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
| Maximum operating rate | 600 cyc/h 55 °C |
| Operating time | 100...170 ms opening 40...75 ms closing |
| Connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 3 cable(s) - busbar cross section: 100 x 5 mm Power circuit: bolted connection |
| Tightening torque | Control circuit: 1.2 N.m Power circuit: 58 N.m |
| Mounting support | Plate |
| Published component type | Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.