Technical specifications
| Manufacturer | Schneider Electric |
|---|---|
| Part number | LC1F2600 |
| Category | Electrical & controls |
| Range | TeSys |
| product name | TeSys F |
| Product or Component Type | Contactor |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz |
| [Ie] rated operational current | 2600 A 140 °F (60 °C)) <= 440 V AC AC-1 |
| [Uc] control circuit voltage | 110...500 V AC 40...400 Hz with LX1/LX9 coil 110...440 V DC with LX4 coil |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 2600 A (at 140 °F (60 °C)) |
| Irms rated making capacity | 3900 A AC conforming to IEC 60947-4-1 |
| Rated breaking capacity | 3900 A conforming to IEC 60947-4-1 |
| [Icw] rated short-time withstand current | 12000 A 104 °F (40 °C) - 10 s 9000 A 104 °F (40 °C) - 30 s 7000 A 104 °F (40 °C) - 1 min 6000 A 104 °F (40 °C) - 3 min 4000 A 104 °F (40 °C) - 10 min |
| Associated fuse rating | 2500 A gG at <= 440 V |
| Average impedance | 0.1 mOhm - Ith 2600 A 50 Hz |
| [Ui] rated insulation voltage | 1000 V IEC 60947-4-1 |
| Power dissipation per pole | 250 W AC-1 |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.2...0.35 Uc DC with LX4 coil |
| Operating time | 40...80 ms closing with LX1/LX9 coil 100...200 ms opening with LX1/LX9 coil 60...70 ms closing with LX4 coil 40...50 ms opening with LX4 coil |
| Mounting Support | Plate |
| Connections - terminals | Power circuit bar 3 100 x 10 mm Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) |
| Tightening torque | Power circuit 513.3 lbf.in (58 N.m) Control circuit 10.6 lbf.in (1.2 N.m) |
| Inrush power in VA | 2200…2700 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 2130…2880 VA (at 68 °F (20 °C))with LX4 coil |
| Hold-in power consumption in VA | 37.4…50.6 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 13…25 VA (at 68 °F (20 °C))with LX4 coil |
| Maximum operating rate | 600 cyc/h 131 °F (55 °C) |
| Published component type | Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.