LC1F265BD — Contactor
contactorPart number: LC1F265BD
LC1F265BD — Contactor — Schneider Electric reference LC1F265BD. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Looking for Schneider Electric LC1F265BD? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | Schneider Electric |
|---|---|
| Part number | LC1F265BD |
| Category | Electrical & controls |
| Range | TeSys |
| Range of Product | TeSys F |
| Product or Component Type | Contactor |
| Poles description | 3P |
| [Ue] rated operational voltage | <= 1000 V AC-1 <= 690 V AC-3 <= 690 V AC-4 <= 460 V DC |
| [Uc] control circuit voltage | 24 V DC |
| [Ie] rated operational current | 350 A (at <104 °F (40 °C)) at <= 440 V AC AC-1 265 A (at <131 °F (55 °C)) at <= 440 V AC AC-3 |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ith] conventional free air thermal current | 350 A (at 104 °F (40 °C)) |
| Rated breaking capacity | 2120 A conforming to IEC 60947-4-1 |
| [Icw] rated short-time withstand current | 2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min |
| Associated fuse rating | 315 A aM at <= 440 V 400 A gG at <= 440 V |
| Average impedance | 0.3 mOhm - Ith 350 A 50 Hz |
| [Ui] rated insulation voltage | 1000 V IEC 60947-4-1 1500 V VDE 0110 group C |
| Power dissipation per pole | 37 W AC-1 21 W AC-3 |
| Overvoltage category | III |
| power pole contact composition | 3 NO |
| Motor power kW | 132 kW at 380...400 V AC 50/60 Hz (AC-3) 140 kW at 415 V AC 50/60 Hz (AC-3) 140 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660...690 V AC 50/60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) 75 kW at 220...230 V AC 50/60 Hz (AC-3) 51 kW at 400 V AC 50/60 Hz (AC-4) |
| Control circuit voltage limits | Operational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.15...0.2 Uc 131 °F (55 °C)) |
| Inrush power in W | 750 W 68 °F (20 °C)) |
| Hold-in power consumption in W | 5 W 68 °F (20 °C) |
| Maximum operating rate | 2400 cyc/h 131 °F (55 °C) |
| Operating time | 40...50 ms closing 40...65 ms opening |
| Connections - terminals | Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end Power circuit bar 2 32 x 4 mm Power circuit lugs-ring terminals 1 0.4 in² (240 mm²) Power circuit connector 1 0.4 in² (240 mm²) Power circuit bolted connectio |
| Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 309.8 lbf.in (35 N.m) |
| Mounting Support | Plate |
| motor power range | 55…100 kW 200…240 V 3 phase 110…220 kW 480…500 V 3 phase 110…220 kW 380…440 V 3 phase |
| Contactor coil voltage | 24 V DC standard |
| Published component type | Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |