ManufacturerSchneider Electric
Part numberLC1F630G7
CategoryElectrical & controls
RangeTeSys
Range of ProductTeSys F
Product or Component TypeContactor
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz <= 460 V DC
[Uc] control circuit voltage120 V AC 40...400 Hz
[Ie] rated operational current1000 A (at <104 °F (40 °C)) at <= 440 V AC AC-1 630 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage8 kV
[Ith] conventional free air thermal current1000 A (at 104 °F (40 °C)) 1250 A
Rated breaking capacity5040 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current5050 A 104 °F (40 °C) - 10 s 4400 A 104 °F (40 °C) - 30 s 3400 A 104 °F (40 °C) - 1 min 2200 A 104 °F (40 °C) - 3 min 1600 A 104 °F (40 °C) - 10 min
Associated fuse rating1000 A gG at <= 440 V 630 A aM at <= 440 V
Average impedance0.12 mOhm - Ith 1000 A 50 Hz
[Ui] rated insulation voltage1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole120 W AC-1 48 W AC-3
Overvoltage categoryIII
power pole contact composition3 NO
Motor power kW335 kW at 380...400 V AC 50/60 Hz (AC-3) 375 kW at 415 V AC 50/60 Hz (AC-3) 400 kW at 440 V AC 50/60 Hz (AC-3) 400 kW at 500 V AC 50/60 Hz (AC-3) 450 kW at 660...690 V AC 50/60 Hz (AC-3) 450 kW at 1000 V AC 50/60 Hz (AC-3) 200 kW at 220...230 V AC 50/60 Hz (AC-3) 100 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limitsOperational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.25...0.5 Uc 40...400 Hz 131 °F (55 °C))
Inrush power in VA1650 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA22 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate1200 cyc/h 131 °F (55 °C)
Operating time40...80 ms closing 100...200 ms opening
Connections - terminalsControl circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end Power circuit bar 2 60 x 5 mm Power circuit bolted connection
Tightening torqueControl circuit 10.6 lbf.in (1.2 N.m) Power circuit 513.3 lbf.in (58 N.m)
Mounting SupportPlate
Published component typeContactor
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

Research is not yet available for this part in English. Ask our team for help.

Get a quote for this part

Make yourself at home.

Choose your language and delivery destination. Final pricing and shipping are confirmed in your quote.