LC1F780F7No product image available

Catalogue reference. Availability, exact specification and OEM or aftermarket supply are confirmed in your quotation.

Schneider Electric

LC1F780F7 — Contactor

contactor

Part number: LC1F780F7

LC1F780F7 — Contactor — Schneider Electric reference LC1F780F7. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Looking for Schneider Electric LC1F780F7? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerSchneider Electric
Part numberLC1F780F7
CategoryElectrical & controls
RangeTeSys
Range of ProductTeSys F
Product or Component TypeContactor
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz <= 460 V DC
[Uc] control circuit voltage110 V AC 40...400 Hz
[Ie] rated operational current1600 A (at <104 °F (40 °C)) at <= 440 V AC AC-1 780 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage8 kV
[Ith] conventional free air thermal current1600 A (at 104 °F (40 °C))
Rated breaking capacity6240 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current3000 A 104 °F (40 °C) - 3 min 6250 A 104 °F (40 °C) - 10 s 5600 A 104 °F (40 °C) - 30 s 4600 A 104 °F (40 °C) - 1 min 2200 A 104 °F (40 °C) - 10 min
Associated fuse rating1600 A gG at <= 440 V 800 A aM at <= 440 V
Average impedance0.1 mOhm - Ith 1600 A 50 Hz
[Ui] rated insulation voltage1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole250 W AC-1 60 W AC-3
Overvoltage categoryIII
power pole contact composition3 NO
Motor power kW450 kW at 1000 V AC 50/60 Hz (AC-3) 400 kW at 380...400 V AC 50/60 Hz (AC-3) 425 kW at 415 V AC 50/60 Hz (AC-3) 425 kW at 440 V AC 50/60 Hz (AC-3) 450 kW at 500 V AC 50/60 Hz (AC-3) 475 kW at 660...690 V AC 50/60 Hz (AC-3) 220 kW at 220...230 V AC 50/60 Hz (AC-3) 110 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limitsOperational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.2...0.4 Uc 40...400 Hz 131 °F (55 °C))
Inrush power in VA2100 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA50 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate600 cyc/h 131 °F (55 °C)
Operating time40...80 ms closing 130...230 ms opening
Connections - terminalsControl circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end Power circuit bar 2 100 x 5 mm Power circuit bolted connection
Tightening torqueControl circuit 10.6 lbf.in (1.2 N.m) Power circuit 513.3 lbf.in (58 N.m)
Mounting SupportPlate
motor power range250…500 kW 380…440 V 3 phase 110…220 kW 200…240 V 3 phase 250…500 kW 480…500 V 3 phase
Contactor coil voltage110 V AC standard 120 V AC standard
Published component typeContactor
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

Research is not yet available for this part in English. Ask our team for help.

Get a quote for this part

Make yourself at home.

Choose your language and delivery destination. Final pricing and shipping are confirmed in your quote.