Component reference image: Published product/series reference; confirm the exact configuration and supplied appearance.

Representative component image—not a photograph of this exact brand or part number. Confirm the specification; the supplied part may look different.

Schneider Electric

LC2D150F7 — Reversing contactor

contactor

Part number: LC2D150F7

LC2D150F7 — Reversing contactor — Schneider Electric reference LC2D150F7. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Looking for Schneider Electric LC2D150F7? This catalogue reference is listed under contactor. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.

Availability on request

Price on quotation

Shipping includedWarranty & serviceGet a quote for this part

Technical specifications

ManufacturerSchneider Electric
Part numberLC2D150F7
CategoryElectrical & controls
RangeTeSys
product nameTeSys Deca
Product or Component TypeReversing contactor
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit <= 1000 V AC 25...400 Hz Power circuit <= 300 V DC
[Ie] rated operational current200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit 150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
Motor power kW40 kW at 220...230 V AC 50 Hz 75 kW at 380...400 V AC 50 Hz 80 kW at 415...440 V AC 50 Hz 90 kW at 500 V AC 50 Hz 100 kW at 660...690 V AC 50 Hz 75 kW at 1000 V AC 50 Hz
motor power HP (UL / CSA)40 hp at 200/208 V AC 60 Hz for 3 phase motors 50 hp at 230/240 V AC 60 Hz for 3 phase motors 100 hp at 460/480 V AC 60 Hz for 3 phase motors 125 hp at 575/600 V AC 60 Hz for 3 phase motors
[Uc] control circuit voltage110 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current200 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1660 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1400 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current250 A 104 °F (40 °C) - 10 min for power circuit 580 A 104 °F (40 °C) - 1 min for power circuit 1200 A 104 °F (40 °C) - 10 s for power circuit 1400 A 104 °F (40 °C) - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1 315 A gG at <= 690 V coordination type 1 for power circuit 250 A gG at <= 690 V coordination type 2 for power circuit
Average impedance0.6 mOhm - Ith 200 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 1000 V IEC 60947-4-1
Power dissipation per pole24 W AC-1 13.5 W AC-3 13.5 W AC-3e
Mounting SupportPlate Rail
Connections - terminalsControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Power circuit connector 1 0.02…0.2 in² (10…120 mm²)flexible without cable end Power circuit connector 2 0.02…0.08 in² (10…50 mm²)flexible without ca
Tightening torqueControl circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Operating time20...35 ms closing 40...75 ms opening
Maximum operating rate1200 cyc/h 140 °F (60 °C)
Control circuit voltage limits0.3...0.5 Uc (131 °F (55 °C)):drop-out AC 50/60 Hz 0.8...1.15 Uc (131 °F (55 °C)):operational AC 50/60 Hz
Inrush power in VA280…350 VA 60 Hz 0.9 68 °F (20 °C)) 280…350 VA 50 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA2…18 VA 68 °F (20 °C)) 0.9 60 Hz 2…18 VA 68 °F (20 °C)) 0.9 50 Hz
Published component typeReversing contactor
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.

Product questions

Research is not yet available for this part in English. Ask our team for help.

Get a quote for this part

Make yourself at home.

Choose your language and delivery destination. Final pricing and shipping are confirmed in your quote.