Representative component image—not a photograph of this exact brand or part number. Confirm the specification; the supplied part may look different.
XPSUEP14AP — Safety module
Electrical & controlsPart number: XPSUEP14AP
XPSUEP14AP — Safety module — Schneider Electric reference XPSUEP14AP. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Looking for Schneider Electric XPSUEP14AP? This catalogue reference is listed under Electrical & controls. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | Schneider Electric |
|---|---|
| Part number | XPSUEP14AP |
| Category | Electrical & controls |
| Range of Product | Harmony Safety Automation |
| Product or Component Type | Safety module |
| Connections - terminals | Removable screw terminal block, 0.2...2.5 mm² solid or flexible Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| [Us] Rated Supply Voltage | 24 V AC - 15...10 % 24 V DC - 20...20 % |
| Power consumption in W | 1.5 W 24 V DC |
| Power consumption in VA | 3.5 VA 24 V AC 50/60 Hz |
| Input protection type | Internal, electronic |
| safety outputs | 4 NO redundant 2 NC single |
| safety inputs | 0 extension bus 24 V DC 5 mA |
| Maximum line resistance | 60 Ohm |
| Input compatibility | Normally closed circuit ISO 14119 XC limit switch ISO 14119 Mechanical contact ISO 14119 Normally closed circuit ISO 13850 Antivalent pair ISO 14119 OSSD pair IEC 61496-1-2 3-wire proximity sensors PNP |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact |
| [Ith] conventional free air thermal current | 8 A |
| Associated fuse rating | 10 A gG NO relay output circuit IEC 60947-1 4 A gG NC relay output circuit IEC 60947-1 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 12 V relay output |
| Maximum response time on input open | 20 ms |
| [Ui] rated insulation voltage | 250 V 2)IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV II IEC 60947-1 |
| Local signalling | LED (green) for power ON LED (red) for error LED (yellow) for safety output status |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 4.7 in (120 mm) |
| Height | 3.9 in (100 mm) |
| Width | 0.9 in (22.5 mm) |
| Product Weight | 0.441 lb(US) (0.200 kg) |
| Published component type | Safety module |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.