Catalogue reference. Availability, exact specification and OEM or aftermarket supply are confirmed in your quotation.
FX3-XTIO84002 — Safety I/O Module
I/O modulePart number: FX3-XTIO84002
The SICK FX3-XTIO84002 is a Flexi Soft safety I/O expansion module with 8 safety inputs, 4 safe outputs and 2 test outputs. It uses spring terminals, supports Flexi Loop and is configured using software. Verify the existing controller and system configuration before replacement.
Looking for SICK FX3-XTIO84002? This catalogue reference is listed under I/O module. Send the part number and your equipment details so we can confirm the specification, availability and a quotation including shipping.
Availability on request
Technical specifications
| Manufacturer | SICK |
|---|---|
| Part number | FX3-XTIO84002 |
| Category | Sensors & automation |
| Item Type Name | Safety I/O Module |
| Product Family / Series | Flexi Soft |
| Part Number | FX3-XTIO84002 |
| module_type | I/O module |
| number_of_safety_inputs | 8 |
| number_of_test_outputs | 2 |
| number_of_safe_outputs | 4 |
| safety_integrity_level | SIL 3 (IEC 61508); SILCL 3 (EN 62061) |
| safety_category | Category 4 (EN ISO 13849) |
| performance_level | PL e (EN ISO 13849) |
| pfhd_single_channel | 4.8 x 10⁻⁹ per hour (EN ISO 13849) |
| pfhd_dual_channel | 0.9 x 10⁻⁹ per hour (EN ISO 13849) |
| mission_time | 20 years (EN ISO 13849) |
| fast_shut_off_time | 8 ms |
| configuration_method | Flexi Soft Designer; Safety Designer for Safe EFI-pro system |
| power_supply | Internal supply via FLEXBUS+; output supply 24 V DC, 16.8–30 V DC |
| internal_power_consumption | ≤ 2.2 W |
| input_voltage_high | 13–30 V DC |
| input_voltage_low | −5 to 5 V DC |
| input_current_high | 2.4 mA to 3.8 mA |
| input_current_low | -2.5 mA to 2.1 mA |
| test_output_voltage_high | 15 V DC to 30 V DC |
| test_output_current | ≤ 120 mA |
| test_pulse_generators | 2 |
| output_voltage_supply | 24 V DC (16.8 V DC to 30 V DC) |
| output_voltage_high | 16 V DC to 30 V DC |
| output_current | ≤ 2 A |
| output_type | PNP semiconductors, short-circuit protected |
| supply_voltage_type | PELV or SELV |
| protection_class | III (EN 61140) |
| connection_type | Plug-in spring terminals |
| flexi_loop_compatible | Yes |
| Ecliss 9 0 | 27249090 |
| Etim 5 0 | EC002632 |
| Etim 6 0 | EC002632 |
| Weight | 164 g (± 5%) |
| Dimensions | 22.5 × 96.5 × 120.6 mm (W × H × D) |
| Reference status | Published catalogue reference; confirm specification and fitment before ordering |
| Availability | On request |
| Ambient operating temperature | −25 to +55 °C |
Catalogue information may contain errors or be out of date. Full specifications and verified details are available on request. Confirm the part number and equipment fitment with us before ordering.
Product questions
How many safety inputs and outputs does the FX3-XTIO84002 provide?
It provides 8 safety inputs, 4 safe outputs and 2 test signal outputs. Its connections use spring terminals.
What system and software does the FX3-XTIO84002 use?
This I/O expansion module is for the SICK Flexi Soft safety control system and is Flexi Loop compatible. Configuration is via Flexi Soft Designer or, for a Safe EFI-pro system, Safety Designer. Confirm the existing controller configuration and serial number before ordering a replacement.
What safety performance is specified for the FX3-XTIO84002?
The module is specified for SIL 3, SILCL 3 and PL e, with Category 4 also listed. The safety level achieved by a complete machine depends on its design and configuration, not the module alone.
Researched on: